WiFi Settings....................13 WiFi System Setup..................14-17 TMX-0100 Installation Procedure............. 14 Connecting to a Wireless Network............15-16 Adding the SNO-0550 to the HBX App........... 17 HBX App Functionality................18 Sample Wiring and Diagrams ............... 19-20 Troubleshooting Guide ................21-23 Warranty Information ................24...
QR CODE Each SNO-0550 is labeled with a QR code, which when scanned will link to a digital version of this manual. If this manual is ever lost or damaged, simply scan this with a compatible device to download the latest manual version.
The SNO-0550 can also be controlled remotely using your smartphone or tablet device with the free HBX Zone App. The HBX Zone App allows you to control your snow melt system with the ability to set snow fall rates, adjust/ monitor targets, set slab demands , and the ability to turn on/off your snow melt system anytime, anywhere.
H B X S N O - 0 5 5 0 S n o w M e l t C o n t r o l V e r s i o n 2 . 0 2 TECHNICAL DATA AND DIMENSIONS Specifications: TMX-0100 TECHNICAL DATA 1 x 5VDC input...
Mounting Holes • Identify the four mounting holes on the SNO-0550, mark on the wall the desired location of mounting. • Predrill, anchor and fasten four screws for mounting.
H B X S N O - 0 5 5 0 S n o w M e l t C o n t r o l V e r s i o n 2 . 0 2 NAVIGATING THE SNO-0550 Relays: All programming steps within the SNO-0550 240VAC 5A Max STATUS are achieved by using the three buttons (and...
CONTROL SETUP Multicolour backlit Display Relays: 240VAC 5A Max STATUS The Multicolour Backlit Display is one of the key features Input: of the HBX Controls stand-alone SNO-0550 Control. TARGET 120VAC 15A Max SLAB °F °F SNO-0550 Depending on which mode of operation is selected the SUPPLY °F...
°F °F Supply Tank Target RETURN °F SNOW OUTDOOR °F NONE SYS P FL UP FL DN SNO-0550 Central Processing Unit SNO-0550 Central Processing Unit DO NOT DO NOT CONNECT 24 VAC MAX CONNECT POWER POWER HERE HERE 12 13...
°F DESIGN TEMPERATURES 50°F 2) MIN SYSTEM 0°F 5) CWSD This is used to set the temperature in which the SNO-0550 will go into WWSD. If the 25°F 1) DELTA T 120°F 3) MAX SYSTEM 6) °C OR °F °F DESIGN TEMPERATURES outdoor temperature rises above this temperature, the control will turn OFF.
H B X S N O - 0 5 5 0 S n o w M e l t C o n t r o l V e r s i o n 2 . 0 2 4) SYSTEM SETTINGS System Setup SETUP MENU This setting is used to configure the demand type and mixing settings.
5) RELAY 3 6) RELAY 4 6) WIFI SETTINGS WiFi Settings SETUP MENU This setting gives the user the capability to use the SNO-0550 remotely with the HBX 1) SNOW RATE SETUP App. 2) DESIGN TEMPS SETUP MENU SETUP MENU...
TMX-0100 (ThermoLinx™ Wi-Fi Module) Installation Procedure The TMX-0100 is designed to be used with the ZON-0550, SNO-0550, and HBX Zone App for remote access. The operational status of the TMX-0100 is indicated by lights (LEDs). The TMX-0100 has three (3) lights on the front (red for Wi-Fi, green for ready, blue for Server).
Page 18
6. Once connected, check the red, green, and blue LED lights on the TMX- 0100. All LED lights should be steady (allow for a couple of minutes). 7. Now you are ready to add the SNO-0550. See Adding the SNO-0550 on page 17.
SNOW-0000 1. On the home screen, select “Add device”. CHANGE PASSWORD 2. Enter the Sync-Code for the SNO-0550. The Sync- Code can be found in the System Setup Menu in option 6) 1) NO 2) YES WIFI on the SNO-0550.
This allows you to toggle the control into Melt Mode, or turn Melt Mode off. 4. Advanced Settings Allows you to have access to all the settings on the SNO-0550 control including snow rate setup, Design temperatures, Slab and System setup.
WIRING DIAGRAMS 1) Snow Melt with Injection Mixing and WiFi Connection SNO-0550 Central Processing Unit DO NOT DO NOT CONNECT 24 VAC MAX CONNECT POWER POWER HERE HERE 12 13 PW TM TM TM *Note: TMX-0100 is only applicable when using Wi-Fi...
Page 22
3) Snow Melt with Floating Action Valve Mixing SNO-0550 Central Processing Unit DO NOT DO NOT CONNECT 24 VAC MAX CONNECT POWER POWER HERE HERE 12 13 PW TM TM TM System Pump System Sensor Return Sensor Optical Sensor Boiler...
Page 24
No communication between modules • CAB-0150 connector is not connected properly to the control • Disconnect the Thermolinx module and power down the SNO-0550 control. Power it up and reconnect the Thermolinx module. If issue persists contact HBX tech support Page 22...
Limitation of Liability In no event will HBX be liable for any damages, including loss of data, loss of profits, costs of cover or other incidental, consequential or indirect damages arising out of the installation, maintenance, commissioning, performance, failure or interruption of an HBX product, however caused and on any theory of liability.