NetGen Communications SmartATA Series User Manual page 62

Table of Contents

Advertisement

SMART ATA
Title
SDP Address
Remote management
Enable/Disable
Management system type
SNMP/TR069
Server
User Name
Password
Provisioning Code
Model Name
Periodic inform enable
Periodic inform interval
Connection Request URL
Page 54
Explanation
This parameter determines the IP address used in transmitted SDP.
External Network IP Address: Smart ATA will use the external/routable
address in the transmitted SDP;
Internal (Local) IP Address: The GW will use the IP address in the
transmitted SDP.
Enable – Selecting Enable means that Autoprovision is to be used. A
window appears that allows the entry of the http or ftp (for example)
URL, possibly of the form http://name:pw@211.168.5.153/auto/$MA/
or ftp://name:pw@211.168.5.153/auto/$MA/. If the server supports
DHCP Option 66, this address may be left blank.
TR069 – TR069 is the "CPE WAN Management Protocol" (CWMP)
specified by the Broadband Forum.. Selecting TR069 reveals
the fields shown above and explained below.
Simple Network Management Protocol (SNMP) is an
"Internet-standard protocol for managing devices on IP
networks". Devices that typically support SNMP include
routers, switches, servers, workstations, printers, modem
racks and more.
Smart ATA may download software upgrade packages and configuration
files automatically through an auto-configuration server (ACS). Once
auto provisioning is selected, you must enter the IP address of ACS here.
Username used to authenticate the CPE when making a connection to the
ACS using the CPE WAN Management Protocol.
This username is used only for HTTP-based authentication of the CPE.
Note that on a factory reset of the CPE, the value of this parameter might
be reset to its factory value. If an ACS modifies the value of this
parameter, it SHOULD be prepared to accommodate the situation that the
original value (TR-098 page 19)
This is the password used authenticate the Smart ATA when it is
communicating with the ACS
Identifier of the primary service provider and other provisioning
information, which MAY be used by the ACS to determine service
provider-specific customization and provisioning parameters.
If non-empty, this argument SHOULD be in the form of a hierarchical
descriptor with one or more nodes specified. Each node in the hierarchy
is represented as a 4-character sub-string, containing only numerals or
upper-case letters. If there is more than one node indicated, each node is
separated by a "." (dot). Examples: "TLCO" or "TLCO.GRP2".
See TR-098, 2.4
Model name of the CPE (human readable string). See TR069m 2.4.
Whether or not the CPE must periodically send CPE information to the
ACS using the Inform method.
Time between sending Inform messages in seconds
HTTP URL for an ACS to make a Connection Request notification to the
CPE. This is typically just the IP address of the Smart ATA (i.e.
http://192.168.16.16)
Configuration Manual
NetGen Communications, Inc.

Hide quick links:

Advertisement

Table of Contents
loading