Parts Arrangement
outdoor fan
(not shown)
top of cabinet
run capacitor
terminal box
high pressure
switch
Setting the Unit
CAUTION
In order to avoid injury, take proper precaution when
lifting heavy objects.
CAUTION
Danger of sharp metallic edges. Can cause injury.
Take care when servicing unit to avoid accidental
contact with sharp edges.
Refer to unit dimensions for sizing mounting slab, platform-
s, or supports. Refer to figure 2 for installation clearances.
compressor
Figure 1
Installation Clearances
NOTE − A service access
clearance of 30" (762 mm)
must be maintained in front
of the service access panel.
Clearance to one side must
be 36" (914 mm). Clearance
to one of the remaining two
sides may be 12" (304 mm)
and the final side may be 6"
(152 mm).
NOTE − A clearance of 24" (610 mm)
must be maintained between two units.
NOTE − 48" (1219 mm) clearance required on top
of unit. Maximum soffit overhang is 36" (914 mm).
Page 3
ground lug
contactor
vapor valve
and gauge port
liquid line
service valve
and gauge port
low pressure
switch
*36"
(914 mm)
36"
36"
(914 mm)
(914 mm)
*36"
(914 mm)
Figure 2