  • Page 1 Enclosures ENC 8/10, ENC 10/12, ENC 12/14, ENC 14/16, ENC 16/18 and AM-ENC/ENCT Issued: 6.9.17 Copyright © 2000-2017 Campbell Scientific Ltd CSL 264...
  • Page 3 Quotations for repairs can be given on request. It is the policy of Campbell Scientific to protect the health of its employees and provide a safe working environment, in support of this policy a “Declaration of Hazardous Material and Decontamination”...
  • Page 5 Campbell Scientific Ltd can advise on the recycling of the equipment and in some cases arrange collection and the correct disposal of it, although charges may apply for some items or territories.
  • Page 7 • Periodically (at least yearly) check electrical ground connections. WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL SCIENTIFIC PRODUCTS, THE CUSTOMER ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER INSTALLATION, USE, OR MAINTENANCE OF TRIPODS, TOWERS, OR ATTACHMENTS TO TRIPODS AND TOWERS...
  • Page 9: Table Of Contents

    Contents 1. Description ..............1 2. Installing Components in the Enclosure ....1 3. Power Supplies ............2 4. Earth Connections ............. 3 5. Sealing the Enclosure ..........3 6. Desiccant ..............3 7. Attachment to an Instrument Mount ......5 7.1 Tripod Mast ....................5 7.2 Tower Mounting ..................7 7.3 Leg Base of a CM110, CM115, CM120 Tripod ........9...
  • Page 10 7-10. An enclosure attached to the leg base of a CM110 tripod ....11 A-1 #15908 DIN-Rail Stopper installation ..........A-1 A-2 #15920 Terminal Strip installation ............ A-2 A-3 #15909 End Plate installation ............A-2 A-4 #15909 Jumper installation ..............A-3 A-5 DIN-Rail bracket mounted onto an enclosure backplate....
  • Page 11: Description

    ENC 14/16, ENC 16/18 and AM-ENC/ENCT Enclosures This manual describes Campbell Scientific’s ENC 8/10, ENC 10/12, ENC 12/14, ENC 14/16, ENC 16/18 and AM-ENC/ENCT enclosures. This information should be used in conjunction with other information given in the datalogger or weather station manuals.
  • Page 12: Power Supplies

    ENC 8/10, ENC 10/12, ENC 12/14, ENC 14/16, ENC 16/18 and AM-ENC/ENCT Enclosures Some peripherals need adaptor plates for these enclosures. The NOTE adaptor plates are not always supplied with the peripheral. Please contact Campbell Scientific if you experience any problems.
  • Page 13: Earth Connections

    (approx. 16mm , similar to that supplied by Campbell Scientific with weather stations, etc.). Internally the earth wire should be connected to the main earth point in the enclosure, which is usually the datalogger wiring panel.
  • Page 14 ENC 8/10, ENC 10/12, ENC 12/14, ENC 14/16, ENC 16/18 and AM-ENC/ENCT Enclosures the closest bags a minimum of 40 cm clearance from the heat shield. Excessive surface film temperature due to infrared radiation will cause the Tyvek material to melt and/or the seals to fail.
  • Page 15: Attachment To An Instrument Mount

    Installation Manual 7. Attachment to an Instrument Mount 7.1 Tripod Mast The mast mount option is intended for mounting our enclosures to the mast of any of our tripods. An enclosure ordered with this option will be shipped with a three- piece bracket for mounting on the top of the enclosure and an identical three-piece bracket for mounting to the bottom of the enclosure (see Figures 7-1, 7-2, and 7-3).
  • Page 16: This Exploded View Shows The Components Of A Mast Mounting Bracket

    ENC 8/10, ENC 10/12, ENC 12/14, ENC 14/16, ENC 16/18 and AM-ENC/ENCT Enclosures Figure 7-2. This exploded view shows the components of a mast mounting bracket. Figure 7-3. An enclosure attached to a tripod mast.
  • Page 17: Tower Mounting

    Installation Manual 7.2 Tower mounting The tower mount option is used to attach our enclosures to UT930, UT920, and ATW towers. An enclosure ordered with the tower mount option will be shipped with a three-piece bracket for fitting to the top of the enclosure and an identical three-piece bracket for fitting to the bottom of the enclosure.
  • Page 18: This Exploded View Shows The Components Of A Tower Mount Bracket Option

    ENC 8/10, ENC 10/12, ENC 12/14, ENC 14/16, ENC 16/18 and AM-ENC/ENCT Enclosures Flange Section Flange Section Figure 7-5. This exploded view shows the components of a tower mount bracket option. Figure 7-6. An enclosure attached to two tower legs.
  • Page 19: Leg Base Of A Cm110, Cm115, Cm120 Tripod

    Installation Manual 7.3 Leg Base of a CM110, CM115, CM120 Tripod The leg mount option is intended for attaching an ENC10/12, ENC12/14, or ENC14/16 enclosure to the leg base of a CM110, CM115, or CM120 tripod. An enclosure ordered with this option will be shipped with a bracket attached to each side of the enclosure and a u-bolt bracket.
  • Page 20: An Enc 14/16 Enclosure With A Leg Mount Bracket

    ENC 8/10, ENC 10/12, ENC 12/14, ENC 14/16, ENC 16/18 and AM-ENC/ENCT Enclosures Notch Figure 7-8. An ENC 14/16 enclosure with a leg mount bracket. Figure 7-9. The u-bolt bracket.
  • Page 21: Resistance To Weathering / Ageing

    (electrical, mechanical or chemical) of the polyester. Enclosures of the type supplied by Campbell Scientific have been successfully used outdoors since 1958 and tests on field samples support laboratory results.
  • Page 22: Enc 8/10, Enc 10/12, Enc

    ENC 8/10, ENC 10/12, ENC 12/14, ENC 14/16, ENC 16/18 and AM-ENC/ENCT Enclosures NOTE As of September 2009, all enclosures will be supplied with a special surface coating to reduce surface ageing. No extra surface treating should be necessary unless the enclosures are exposed to extreme...
  • Page 23 Appendix A. DIN rail terminal kits A.1 Introduction The 006706-002 (5-inch) or #28532 (9-inch) kit can facilitate wiring when many wires need to be connected to one terminal. The kit contains one #15906 5-inch DIN-Rail (or one #28531 9-inch DIN-Rail) Mounting Bracket, #505 screws, #6044 grommets, and #15908 DIN-Rail Stoppers.
  • Page 24 Appendix A. DIN-rail terminal kits Figure A-2. #15920 Terminal Strip installation Figure A-3. #15907 End Plate installation Insert the #15909 Jumpers in the terminal strips as shown in Figure A-4.
  • Page 25 Appendix D. Default Programs Figure A-4. #15909 Jumper installation Mount the DIN-Rail bracket onto the enclosure backplate using two #505 screws and two #6044 grommets (see Figure A-5). NOTE The 006706 includes three screws and three grommets. Use the third screw and grommet to secure the 9-pin DIN-Rail at its centre.
  • Page 26 Appendix A. DIN-rail terminal kits Figure A-6. An installed and wired 006706-002 DIN-Rail Terminal Kit Figure A-7. The 006706-002 DIN-Rail Terminal Kit facilitates wiring of multiple sensors...
  • Page 28 CAMPBELL SCIENTIFIC COMPANIES Campbell Scientific, Inc. (CSI) 815 West 1800 North Campbell Scientific Centro Caribe S.A. (CSCC) Logan, Utah 84321 300N Cementerio, Edificio Breller UNITED STATES Santo Domingo, Heredia 40305  COSTA RICA www.campbellsci.com info@campbellsci.com  www.campbellsci.cc info@campbellsci.cc Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Campbell Scientific Ltd.