The CPU (IC801) is programmed so the set will go to the standby mode when there is a circuit failure as described below.
(Refer to"Power Supply Lines" page 38.)
1. Power Failure 1:
(Normal: High, Failure: Low)
2. Power Failure 2:
(Normal: Low; Failure: High)
3. Power Failure 3:
(Normal: High, Failure: Low)
4. Temperature Failure:
(Normal: Low, Failure: High)
LED Flashing
Note: If power failure is detected 3 times in 15 minutes, the set will enter the standby mode and cannot be
switched On. To reset the operating programs of the CPU it is necessary to disconnect the AC cord
for a short time.
History of Power Failure
When finishing the repair or stopping the Power Failure, the history of past failures can be checked.
To see the history
1. Enter the service mode. See "Service Adjustments" page 3.
2. Select Item No. 355 POWER ERROR from the Service Adjustment Data Table.
History of Power Failures (Item No. 355)
Note: If simultaneous failures have been detected, the sum of each data is displayed.
For example:
Power failures 1 & 2
01h + 10h = 11h(17)
Attention:
After finishing service, reset the data of Item No. 355 with the
POWER FAILURE CIRCUIT
Detected voltage failure for analog circuit. (Connected to IC801 pin 52.)
Detected voltage failure for Audio AMP IC. (Connected to IC801 pin 53.)
Detected voltage failure for digital circuit. (Connected to IC801 pin 54.)
Detected temperature failure for Main Power Unit. (Connected to IC801 pin 57.)
— 13 —
<
>
or
keys to "00h(0)."