3. Specification
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
* For repair, contact your local Mitsubishi Electric representative.
• Do not drop the product or exert strong impact to it.
Doing so may cause damage.
DISPOSAL
PRECAUTIONS
• Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
TRANSPORTATION AND
STORAGE PRECAUTIONS
• The product is a precision instrument. During transportation, avoid impacts
larger than those specified in the general specifications by using dedicated
packaging boxes and shock-absorbing palettes. Failure to do so may cause
failures in the product. After transportation, verify operation of the product
and check for damage of the mounting part, etc.
3.1 Applicable PLC
Model name
Applicability
FX
Series PLC
Ver. 2.70 and later
3U
FX
-32MT-LT(-2) PLC
Ver. 2.70 and later
3UC
3.2 General Specifications
Items other than the following are equivalent to those of the PLC main unit.
For general specifications, refer to the manual of the PLC main unit.
→ Refer to the FX
Series User's Manual - Hardware Edition.
3U
→ Refer to the FX
Series User's Manual - Hardware Edition.
3UC
3.3 Power Supply Specification
Item
Specification
20mA
5V DC power supply (mA)
(5V DC power is supplied internally from the main
unit.)
3.4 Performance Specification
Item
Specification
Analog volume points
8 points
VRRD(FNC 85) Volume Read
Instruction
VRSC(FNC 86) Volume Scale
VRRD instruction: 0 to 255
Digital conversion value
VRSC instruction: 0 to 10
4. Program Example
For details on the VRRD and VRSC instruction, refer to the following manuals.
→ Refer to the FX
/FX
/FX
/FX
/FX
Series Programming Manual.
3S
3G
3GC
3U
3UC
1) Example in which the read analog value is used as the set value of an analog
timer. (VRRD instruction)
The analog value of the variable analog potentiometer No.0 is converted into
binary 8-bit data, and the value in the range from 0 to 255 is transferred to D0.
The value of D0 is used as the set value of a timer
Volume
Read
number
destination
X000
FNC 85
K0
D0
VRRD
X001
D0
T0
When a value larger than 255 is required as the set value of a timer, the read
value multiplied by a constant by the FNC22 (MUL) instruction can be set
indirectly as the timer constant.
2) Example in which the scale value is used as a rotary switch. (VRSC instruction)
Either one among auxiliary relays M0 to M10 turns ON in accordance with the
scale value in the range from 0 to 10 of the specified variable analog
potentiometer.
X000
FNC 86
K1
D1
VRSC
The FNC41 (DECO)
X001
FNC 41
instruction occupies
D1
M0
K4
DECO
auxiliary relays
M0 to M15.
M0
M0 turns ON when the scale value is "0".
M1
M1 turns ON when the scale value is "1".
M10
M10 turns ON when the scale value is "10".
5. Trimmer Layout Label
The trimmer layout label is adhere it in a position where it can be seen easily for quick
reference (as shown in the figure below).
• In the case of FX
3U
Series PLC
VR
VR
0
1
VR
VR
2
3
VR
VR
4
5
VR
VR
6
7
• In the case of FX
-32MT-LT(-2) PLC
3UC
VR
VR
0
1
VR
VR
2
3
VR
VR
4
5
VR
VR
6
7
6. Caution On Use
• Only one analog volume expansion board can be used per main unit.
• The communication function is not available at ch1 when VRRD or VRSC
instruction is used in the program in FX
3U
/FX
3UC
PLCs.
「电器电子产品有害物质限制使用标识要求」的表示方式
Note: This symbol mark is for China only.
含有有害6物质的名称, 含有量, 含有部品
本产品中所含有的有害6 物质的名称, 含有量, 含有部品如下表所示。
 
产品中有害物质的名称及含量
有害物质
部件名称
六价铬
多溴联苯
(Pb)
(Hg)
(Cd)
(Cr(VI))
(PBB)
外壳
可编程
控制器
印刷基板
×
本表格依据SJ/T 11364的规定编制。
○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572
规定的限量要求以下。
×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T
26572规定的限量要求。
基于中国标准法的参考规格:GB/T15969.2
多溴
二苯醚
(PBDE)
This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for
accidents, and compensation for damages to products other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
and other tasks.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN