1|Product Review
The NextCentury TR-201 (Transceiver) is an easy to use, full-feature
device developed to remotely collect meter reads. It can be
connected to either a passive or active pulse-output meter. A
Transceiver can send/receive recorded data to/from a GW-301
Gateway, and comes with a replaceable lithium battery. The TR-201
Transceiver has the longest range in its class with easy to understand
LED light indicators. Indicators allow for immediate verification of
transmission delivery during setup/maintenance.
1.1 - TR-201 Hardware
Figure 1 TR-201 Hardware
A Battery
B Tamper Button
C Test Button D Degson Connector (Blue)
E Signal Status LED F Mounting Plate
G Plastic Release Tab
2|Specifications
2.1 - Dimensions:
74.7mm x 40.3mm x 29.1mm
2.9in x 1.6in x 1.1in
2.2 - Operation enviorment:
-28C to 60C
-20F to 140F
Up to 90% relative humidity (non-condensing)
Must be installed in an indoor environment
2.3 Certifications:
FCC: 2A8BI-TR-20-214
IC: 20949-TR20214
2.4 Typical battery life:
6 years average
Note: Typical battery life assumes constant operating temperatures are
between 70°F and 90°F. Battery life may be reduced with operation outside of
this range.
3|Installations and Setup
3.1 - Connect Transceiver to Meter
Note: If connected to an active pulse meter that has a polarity pulse output,
the positive (+) wire should be placed in the Degson Connector, so when the
Degson Connector is placed on the Transceiver board, the positive wire is
aligned with the (+) indicator on the board.
Figure 2 Connect Transciever to Meter
A Wire Slot B Degson Connector (Blue)
3.2 - Mount the Transceiver
Each Trasnceiver comes with a mounting plate and can be installed in
one of three different ways
Note: Ensure the wiring enters through the wire slot (Figure 2-A), allowing the
top Transceiver plastic cover to be closed completely.
support@nextcenturymeters.com
www.nextcenturymeters.com
Connect a Transceiver to a meter as follows:
1.
Open the Transceiver plastics by pressing in on the plastic
release tab (Figure 1-G) while lifting away the cover.
2.
Remove the Degson Connector (Figure 1-D) from the
Transceiver board by pulling up on it.
3.
Insert the stripped colored wire ends from the meter into
the two-terminal Degson Connector. If a Degson
Connector is already present, ensure the wires are
seated/fastened firmly in place.
4.
Use a small Phillips screwdriver to tighten the screws that
secure wires to the Degson Connector.
5.
Place the Degson Connector back onto the Transceiver
board as shown in Figure 2.
.
1.
NextCentury's M201C and M201CH meters have a
mounting plate that can be attached to them. Simply slide
the Transceiver onto the mounting plate. When using this
method, the Transceiver mounting plate (Figure 1-F) can be
discarded.
2.
Remove the 3M double-sided protective cover and place
the Transceiver mounting plate (Figure 1-F) on a clean wall.
3.
Use the mounting screws and anchors to secure the
Transceiver mounting plate (Figure 1-F) to the wall.
V. 101717

Advertisement

loading

Summary of Contents for NextCentury TR-201

  • Page 1 Figure 1 TR-201 Hardware A Battery B Tamper Button Figure 2 Connect Transciever to Meter C Test Button D Degson Connector (Blue) A Wire Slot B Degson Connector (Blue) E Signal Status LED F Mounting Plate G Plastic Release Tab 3.2 - Mount the Transceiver Each Trasnceiver comes with a mounting plate and can be installed in one of three different ways 2|Specifications NextCentury’s M201C and M201CH meters have a 2.1 - Dimensions: mounting plate that can be attached to them. Simply slide • 74.7mm x 40.3mm x 29.1mm the Transceiver onto the mounting plate. When using this • method, the Transceiver mounting plate (Figure 1-F) can be 2.9in x 1.6in x 1.1in discarded. 2.2 - Operation enviorment: Remove the 3M double-sided protective cover and place •...
  • Page 2 Open the Transceiver plastics by pressing in on the plastic release tab (Figure 1-G) while lifting away the top cover. Remove the previous battery. Insert the new battery in the orientation indicated on the battery terminal. Note: A TR-201 Transceiver permanently retains pulse data in non-volatile memory. Reprogramming the Transceiver is not necessary once a new battery is placed in the transceiver. Once the new battery is placed into the TR-201 Transceiver it will automatically “Sync” to its GW-301 Gateway. Even though re-programming is not necessary, the initial meter read should be reset to Figure 3 Mount the Transceiver allow for matching meter reads between the “NextCentury Cloud” and the meter.
  • Page 3 Email: support@nextcenturymeters.com original manufacturer. NextCentury’s warranties do not include replacement of batteries used to power NextCentury products. Limits of Liability This warranty only applies to Read Management System components produced by NextCentury, and does not cover any products which have been damaged by misconduct, negligence, vandalism, acts of God, excessive operating conditions, or unauthorized attachments or modifications. This warranty will be nullified and void if products are placed in non-recommended installation application/fashion, or are converted, altered, or treated by other than NextCentury recommended procedures and instructions, or are read by equipment not approved by NextCentury.