5.

Operation of button (table 2)

Function
Command
Press briefly
Pairing
(1 s approx)
Press and
Unpairing
hold (10 s
approx)
Press and
Reset
hold (25 s
approx)
6.

Troubleshooting

1) There is no reading of power generated by the photovoltaic system
Check that only the phase wire passes through the CT of the Energy Meter RC
9
Turn the direction of the CT through 180 degrees
9
2) Grid power transfer is not being read correctly
Check that only the phase wire passes through the CT of the Energy Meter
9
Turn the direction of the CT through 180 degrees
9
3) The reading of the power drawn by the load is a negative value:
Turn the direction of the CT through 180 degrees
9
4) During the Energy Meter RC pairing procedure, no other device is detected
Check that the Led of the device is coloured red and blinking
9
Check the distance between Elios4you Smart and Energy Meter, and if necessary, move the meter closer or install a repeater
9
7.

Technical specifications

General specifications
Power supply
Radio specifications
Measurements
Connections
CT
Ambient parameters
Degree of protection
Conformity
Dimensions (L x H x D)
Meaning
Activates pairing of Energy Meter RC with Elios4you Smart
Energy Meter RC no longer paired with Elios4you Smart
The Reset function restores the parameters of the device to the factory settings. All stored data will
be deleted
ZigBee single-phase power meter with data transmission
90/250 Vac; 1 W; 50/60 Hz
Frequency: 2405 MHz to 2480 MHz
Compatible with IEEE 802.15.4
Transmission power; +3 dBm ERP (2 mW)
Internal antenna
Radio range 20 m indoors / 50 m outdoors. Note: the distance is indicative and may vary with
ambient conditions (dimensions and material of walls / floor slabs, etc.)
Bidirectional active power [W]
Bidirectional energy [Wh]
Screw terminals (5.08 mm pitch)
Ø 15 mm - 100/33 mA
Operating conditions: -10 to +60°C; <80% R.H. n.c.
Storage conditions: -20 to +70°C; <80% R.H. n.c.
IP20
Community Directives 2006/95/EEC, 89/336/EEC, 99/5/EEC; ETSI-EN 300 328; ETSI EN301 489;
EN50371; EN60950-1; EN61000-6-2; EN6100
53.5 x 110 x 62 mm