Salamander CT FORCE series Installation And Warranty Manual page 3

Ct range of pumps
Table of Contents

Advertisement

Pre-installation Checklist
Our pre-installation guidelines are detailed on the following pages, but some of the key
"do's and don'ts" are highlighted below:
Do's
 Locate the pump next to the hot water cylinder within 5m of measured pipe. 2m MAX of
15mm pipework on inlet connections may be used.
 Allow 100mm on all sides for ventilation
 Ensure pump is protected from frost
 If servicing two or more bathrooms, cold water supply to the cylinder
must be in 28mm pipework
 Ensure adequate cold water storage (227 litres (50 gal) per bathroom,
364 litres (80 gal) for one bathroom and one en-suite)
 Cold water supplies to the pump must be taken from the opposite side of
the cold water storage cistern to the cold water mains inlet
 Multiple cold water storage cisterns must be linked in accordance with current
plumbing regulations and the bottom of the cisterns must be at the same level
 Hot water supply to the pump must be via a Salamander approved method.
 AV couplers must only be finger tight plus one quarter turn
 The maximum static head should be 10m (equivalent to 1.0bar pressure)
 We recommend the pump is activated for at least 5 minutes every 4 weeks
to ensure pump does not seize.
 Ensure that installation complies with IET wiring regulations.
 All AV hoses should be fitted straight with no twists or bends.
 Ensure suitable means of isolation for maintenance
 Bathroom Zones: Salamander products covered in these notes cannot be installed
in Zone 0 or Zone 1. They can however be installed in areas that are accessible with
a tool. (see Step 1 Pump Location for further information (Fig 5))
2
Pre-installation Checklist
Don'ts
 Never fit the pump to the cold water mains
 Never fit the pump to shared incoming mains supplies to a block of flats
 Never use a shared water supply
 Never put a non-return valve (NRV), restrictive ballofix or an air vent on supply
pipe work to the pump
 The hot water supply must not exceed temperature stated in the installation guide
 Never use mechanical tools to tighten plastic coupler nuts as this may cause damage
and invalidate your warranty
 Never use jointing compounds, Boss White, Hemp or steel wool
 Solder fluxes must not come into contact with the pump or AV couplers
 Never pump directly to or from any pump such as secondary return pump
 Never fit pump to a Fortic, Primatic cylinder or Andrews type water heater.
 If considering fitting pump to a Horizontal (torpedo) water cylinder then please
contact PumpWise on 0191 516 2002
 Never fit the pump to a secondary tapping without a dip tube into the hot water cylinder
(continued)