  • Page 1 Pump installation and warranty guide for the CT range of pumps CT FORCE, CT Xtra, and CT Bathroom Models shown: CT FORCE 15TU CT50 Xtra CT60B...
  • Page 2: Table Of Contents

    DO NOT REMOVE YOUR PUMP FROM THE SYSTEM WITHOUT FIRST RINGING PUMPWISE ON 0191 516 2002 (01844-3212 ROI). PumpWise Guidelines We encourage installers to consult Salamander’s Pumpwise helpline, where our advisers can give you first-rate advice regarding installation. Consulting the helpline at the time of General specifications installation, may entitle your customer to an additional 1 year FREE warranty cover (UK Only) for CT Xtra &...
  • Page 3  If considering fitting pump to a Horizontal (torpedo) water cylinder then please  Hot water supply to the pump must be via a Salamander approved method. contact PumpWise on 0191 516 2002  AV couplers must only be finger tight plus one quarter turn...
  • Page 4: Product Description

    PumpWise on 0191 516 2002 (01844-3212 ROI). Outlet The anti-vibration hoses must not be twisted Do not use Salamander pumps for applications other than those stated within the pump or bent. description, or connect the pump directly to the cold mains.
  • Page 5: Step 1: Pump Location

    If the pump experiences aeration or low pressure as a ¾ inch no stop Essex flange, or a Salamander S flange or other approved top entry flange is result of poor flow to the pump with the use of a top entry flange, a side entry or Essex flange fitted.
  • Page 6 (610mm) or less, it is also possible that a universal pump will be required. Salamander’s discharged from inlet pipework and pump chambers. This will not happen if the outlet universal range of pumps activate the pump automatically even where insufficient natural pipework is connected to the pump.
  • Page 7: Step 2: Connecting The Pump

    Step 2: Connecting the pump Step 3: Electrical installation Use only Salamander supplied AV couplers to connect the pump. Your pump must be connected to the electrical supply using the main cable with the attached plug. This plug must be connected to an accessible socket that has been installed in All associated pipework MUST be thoroughly flushed before making final connections compliance with IET Wiring Regulations.
  • Page 8 (WSP) may be considered (See fig 11). 102mm The WSP is a Salamander level switch which Aeration of pump and cylinder from a cold water storage cistern must be positioned 102mm higher than the This occurs when the incoming cold mains ball valve is positioned above the cold feeds highest outlet from the cold water storage to the cylinder and to the pump –...
  • Page 9 In systems where the stored hot water temperature cannot be controlled e.g. Aga solid fuel appliance or very crudely by the boiler thermostat, a Salamander approved HWS TMV must Figure 15: Water hammer protection be used.
  • Page 10: General Specifications

    – see below. Applications All Salamander pumps are designed to boost low pressure hot and cold supplies from cistern- Figure 16: HWS blending valve controller to pump fed services. When supplies from a water heater or a combination boiler are to be boosted contact the Salamander PumpWise helpline on 0191 516 2002 for guidance.
  • Page 11: Technical Specifications

    ¾” 22mm 6.79 8.10    Salamander has engineered this product range to be as quiet as possible, however no pump Force 30ITU Positive and Negative (2.2) (2.6) (3.0) 21mm is completely silent. Correct installation (anti-vibration couplers straight, rubber feet fitted) Head Shower Pump will minimise noise, vibration and transmission noise.
  • Page 12 Technical Specifications - CT Xtra Technical Specifications - CT Xtra H & HU, CT Bathroom B & BU Part No. Description Specification Performance Connection Type Pump Volumetrics Packed Pump Part No. Description Specification Performance Connection Type Pump Volumetrics Packed Pump Volumetrics Volumetrics Electrical...
  • Page 13: Trouble Shooting

    PumpWise helpline 0191 516 2002 Check fuse Check circuit breaker PumpWise from Salamander helps customers and provides a support service second to none. Installers and customers can be sure of a speedy response to requests for technical help Debris under flow switch...
  • Page 14: Warranty

    (UK only). satisfaction, please assist the customer in completing warranty registration. PLEASE NOTE: Please note that Salamander Pumps are able to provide an onsite service visit which may be Incorrect installation WILL invalidate the pump warranty chargeable.
  • Page 15 In the event of a claim for repairs or replacement being made under the terms of this Warranty, a visit from a Salamander service engineer may be necessary. Engineer visits are not covered under/part of the warranty agreement. In circumstances where in the opinion of the Company the defect has not been caused by the Company’s...
  • Page 16 Notes Notes...
  • Page 17 Get in touch, we’re here to help call us on 0191 516 2002 Unit 2c Colima Avenue Enterprise Park West Sunderland, SR5 3XE Register your warranty Apply online at: www.salamanderpumps.co.uk Apply by phone: 0191 516 2002...