Using a Viking Model RC-4A for Secure Remote Relay Control
12V DC Adapter
(included)
Door / Gate Examples:
Door near Entry Phone 1
Relay 1 Output Contacts
(5A@30VDC / 250VAC max)
Connect to Doorstrike,
120V AC
Mag Lock, Gate Controller, etc.
Doorstrike /
Magnetic Lock
2 Gel-Filled Butt
Connectors (included)
Gate near Entry Phone 1
Relay 2 Output Contacts
(5A@30VDC / 250VAC max)
Connect to Gate Controller, etc.
Gate Controller
(Power typically not
required for gate controllers)
Door near Entry Phone 2
Relay 3 Output Contacts
(5A@30VDC / 250VAC max)
120V AC
Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
Doorstrike /
Magnetic Lock
2 Gel-Filled Butt
Connectors (included)
The front panel of the K-1900-8-IP is mounted using security Torx screws to help prevent intruders from removing the panel
and accessing the on board door strike/gate control relays. For applications requiring additional security, a Viking model
RC-4A remote relay controller can be used. The relay controller is mounted securely inside the building and connected to
the same LAN as the K-1900-8-IP. The on board door strike relays would not be used in this case as the K-1900-8-IP will
send an encrypted message to the RC-4A to activate its relays which control the door strikes/gates.
Up to 4 K-1900-8-IP's can communicate with one RC-4A allowing you to securely control four entrances.
When using a RC-4A for remote relay control, the K-1900-8-IP's relays should be set to "External" in the PC programming.
For more information, see DOD# 582 at www.VikingElectronics.com.
VIKING
NETWORK ENABLED
RELAY CONTROLLER
1
IN1 C IN2 IN3 C IN4
RELAY 1
RELAY 2
1
2
3
4
5
6
LED 1
LED 2
COM.
N.O.
COM.
N.O.
2 Gel-Filled Butt
Connectors (included)
COM.
N.O.
MODEL RC-4A
©
VIKING
ELECTRONICS
HUDSON, WI 54016
2
3
4
5
6
STATUS
LED
RELAY 3
RELAY 4
LOGIC LEVEL
PROGRAMMING
RESTORE DEFAULTS
SPARE
7
8
9 10 11 12
1 2 3 4
NETWORK
LED 9
LED 6
LED 7
LED 8
LED 5
LED 3
LED 4
on
1
2
3
4
Sensor
Examples:
Door Sensor
Gate Sensor
Door Sensor
Door Sensor
Door near Entry Phone 3
Relay 4 Output Contacts
250VAC max) Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
COM.
N.O.
2 Gel-Filled Butt
Connectors (included)
6
SIP VoIP PBX,
SIP Cloud based
Service Provider
Switch
or
PC with SIP
Server Software
PoE
Switch
K-1900-8-IP
Entry Phone 2
IN1 C IN2 IN3 C IN4
1
2 3 4 5 6
K-1900-8-IP
Entry Phone 4
(5A@30VDC /
120V AC
Doorstrike /
Magnetic Lock
Internet
K-1900-8-IP
Entry Phone 1
K-1900-8-IP
Entry Phone 3