Page 1
DIGITAL MULTIMETER MODEL CDM-45 Part No.4500065 OPERATING INSTRUCTIONS 0404 DIGITAL MULTIMETER MODEL CDM-45 Part No.4500065 OPERATING INSTRUCTIONS 0404...
Page 2
Ensure replacements are of the same size and value as the original. For Spare Parts and Service, please contact your nearest dealer, or CLARKE International, on one of the following numbers. Fuse : F200mA / 250V (quick acting) PARTS &...
Page 3
1. If the resistance value being measured exceeds the maximum value of the range selected, an over-range indication will be displayed(“1”). Thank you for purchasing this Clarke Multi-Range Digital Multimeter. Select a higher range. This instrument is a compact, rugged, battery operated hand held 3½ digit, For resistance of approx.
Page 4
SAFETY PRECAUTIONS DC Current Measurement WARNING, Do not attempt to measure a current in excess of 10 Amps Read this information before using the meter, taking special care regarding any WARNING or IMPORTANT notices. The following safe practices and proper 1.
Page 5
OPERATION SPECIFICATIONS Accuracies are ± (% reading ± the number indicated in the 1. Check the 9-volt battery by setting the ON-OFF switch to ON, if the respective chart, added or deducted from the digit, or right hand battery is weak, a + - sign will appear on the display. If this does not column of the reading) appear on the display, proceed as below.
Page 6
DC Current Resistance Range Accuracy Resolution Range Accuracy Resolution 1µA ±0.8% of rdg ± 3 digits 200Ω 0.1Ω ±0.8% of rdg ± 1 digit 20mA 10µA 2KΩ 1Ω 0.1mA 200mA ±1.5% of rdg ± 1 digit 20KΩ 10Ω ±0.8% of rdg ± 1 digit 10mA ±2% of rdg ±...