Balcrank Director Jr. 3110-031 Operation, Installation, Maintenance And Repair Manual page 15

3110 series, 24v dc output
Table of Contents

Advertisement

Symptom
5. System has power and
goes into ready mode,
but no fluid can be
dispensed.
6. Fluid does not cut off
at the correct preset
7. Remote "Ready" light
will not come on, but
the console "Ready"
light does.
14
Cause
Pump is not operating.
Out of fluid.
Control solenoid valve not
operating.
Outlet of pump is blocked.
Defective station selector
switch.
System not properly wired.
Cable not connected or properly
seated.
Impulse meter set up for the
wrong units.
Impulse meter cam plate not
actuating pulse switch at each
cam lobe. The pulse switch is
out of position.
Defective unit.
Remote "Ready" light bulb
burned out.
Remote "Ready" light improperly
wired or faulty wiring.
Solution
Check the air supply to the pump
and the pump air solenoid valve.
Check the fluid level in the storage
container.
Check valve for energized position.
Check impulse meter and control
solenoid valve for blockage.
Return the unit for repair.
Recheck electrical connections and
rewire as specified.
Plug in cable connector.
Check the impulse meter for the
correct volume per pulse.
Check the position of the pulse
switch in relation to the cam lobes.
Also check for broken cam lobe.
Adjust or replace as required per
meter instructions.
Return the unit for repair.
Replace bulb.
Correct or replace remote wiring.