CROSSLINC
REMOTE
set-uP Menu
To enter the set-up menu:
To enter the set-up menu, use paper clip to press the small button
FIGURE B.4
located below the Display on the case front.
arc hours
The first option in the setup menu will be for Arc Hours. If this
option is turned "ON", accumulated arc hours will be displayed on
power up. When in the setup option for Arc Hours the display will
FIGURE B.5
show the following:
To enable Arc Hours display, turn the control knob to the right
while in this menu. To disable Arc Hours display, turn the control
knob left.
The factory default for Arc Hours is "OFF".
VoltMeter/aMMeter holD tiMe
The CrossLinc Remote will display the actual amperage or voltage
after welding has stopped. The hold time option will hold these
values for either 10 seconds or 300 seconds. When in the setup
option for hold time, the display will show the following:
Setup Button
To set the hold time to 10 seconds, turn the output control knob to
the left. To set the hold time to 300 seconds, turn the output
control knob to the right.
The factory default is 10 seconds.
cV FeeDbacK
When being used in a constant voltage mode, the CrossLinc
Remote can be set to display either actual voltage or actual
current during welding and during the hold time. When in the
setup menu for CV Feedback, the display will show the following:
The feedback type is indicated by which LED is lit, either "A" or
"V". If the "A" LED is lit while in this menu, the CrossLinc Remote
will display actual current while welding in a CV mode. If the "V"
LED is lit, the CrossLinc Remote will display actual voltage while
welding in a CV mode.
To choose current, turn the output control knob to the left. To
choose voltage, turn the output control knob to the right.
The factory default is voltage.
13
OPERATION
FIGURE B.6
FIGURE B.7