Download Print this page

Laukhuff S.1 User Instructions page 6

Universal slider action solenoid

Advertisement

Page 6
User Instructions
Universal Slider Action Solenoid S.1
V2.0 – HW rev. 15 – SW rev. 1.7
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8
(standard)
Lowest
Highest
speed
speed
Remember that a higher speed also increases the magnets' current consumption. Especially
Attention:
the highest levels 6 to 8 can dramatically increase power consumption, e.g. from 2 A on level 3 to 4 A on
level 8.
Feature 7: DIAGNOSTICS
The diagnostics function allows testing of the light barrier, input, button and RS output functions.
LED 1  end position sensor OFF
LED 2  track sensor OFF
LED 3  track sensor ON
LED 4  end position sensor ON
LED 5  button
LED 6  ON (RS) input
LED 7  OFF input
LED 8  RS output
Feature 8: ERROR RESET
The S.1 saves error conditions and indicates them with LED 8 or the flashing Error-LED. This feature
allows fast and easy detection of even transient problems.
To delete the error messages saved to the system, simply press the RESET button.
The saved errors are also deleted when the TEACH process is started.
Feature 9: ERRORS
When the switch is this position, the LEDs indicate the nature of the problem:
LED 1  blockage in ON direction
LED 2  blockage in OFF direction
LED 3  maximum force moving to ON
LED 4  maximum force moving to OFF
Aug. Laukhuff GmbH & Co. KG
August-Laukhuff-Straße 1
D-97990 Weikersheim
Telephone: +49 7934/9160-0
Fax: +49 7934/616
E-Mail: info@laukhuff.de
www.laukhuff.de

Advertisement

loading