Page 1
Set button control signal The S.1 magnet sets the benchmark for the most advanced generation of slider solenoids. It uses four optical sensors for measuring the motion speed of the slider. The automatic force adjustment feature sets the perfect speed assuring that the magnet comes to a soft and silent stop at the end position. The control circuitry readjusts the force in case of load changes so that the slider moves at optimum speed and reaches the exact end position without fail.
Page 2
Page 2 User Instructions Universal Slider Action Solenoid S.1 V2.0 – HW rev. 15 – SW rev. 1.7 For dual action: Dual action RS mode Dual action ON-OFF mode Positive input Positive input The RS-OUT provides a signal to the capture system to indicate stop engagement.
Page 3 User Instructions Universal Slider Action Solenoid S.1 V2.0 – HW rev. 15 – SW rev. 1.7 Operating Modes and Functions Feature 0: RUN This is the standard operating mode. For testing, press the set button to move the magnet to the opposite position.
Page 4 User Instructions Universal Slider Action Solenoid S.1 V2.0 – HW rev. 15 – SW rev. 1.7 Feature 3: MODE (A) The slider action solenoid has different operating modes for different applications Mode 1 Mode 2 Mode 3 Mode 4...
Page 5
Switch position 6 allows for the adjustment of the slider motion speed in 8 levels. Standard speed setting is level 3. On this level, the operating noise is kept at a minimum. The S.1 magnet runs at reduced speed to avoid the typical thump during slider switching. It comes to a smooth stop at its end position and so enables an almost noiseless stop action.
Page 6
LED 8 RS output Feature 8: ERROR RESET The S.1 saves error conditions and indicates them with LED 8 or the flashing Error-LED. This feature allows fast and easy detection of even transient problems. To delete the error messages saved to the system, simply press the RESET button.