Download Print this page

BEA BODYGUARD III GT 300 Quick Setup Manual page 2

Presence sensor for pedestrian doors

Advertisement

6 Sensing Zone Adjustment
Pattern Width (Open / Closed)
1: Wide (CLOSED DOOR)
2: Middle (OPEN DOOR)
3: Asymmetric Left Narrow
1ST ROW OF IR
THRESHOLD
2ND ROW OF IR
1
3RD ROW OF IR
4TH ROW OF IR
4
7
NOTE: When pattern width or depth is changed, a setup of the new pattern size will automatically be triggered
once a value key has been pressed.
7 Configurations
8 Door Control Connections
SWING
ACT
Besam 300
13
Besam M/P
3
Yellow
DOM
GT 300/400
Black
6 Black
GT MAG
HORTON 4190
2
9 Company Contact
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc. If you must wait for the
following workday to call BEA., leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or
gate for an incomplete solution. The following numbers can be called 24 hours a day, 7 days a week. For more information, visit www.beasensors.com.
Page 2 of 2
Pattern Width, Depth & Sensitivity all
have independent door closed and
door open values.
4: Asymmetric Right Narrow
7: Asymmetric Left Wide
5: Narrow Left
8: Asymmetric Right Wide
6: Narrow Right
9: Center Narrow
2
5
8
ENSURE COMPLIANCE WITH ALL APPLICABLE CURRENT SAFETY STANDARDS (I.E. ANSI A156.10).
BUTTON
PARAMETER
SENSITIVITY
Door Closed = 6
Door Open = 7
AUTO LEARN
0 = 30 sec
9 = Infinite
OUTPUT CONFIG.
NO
NC
IMMUNITY
Low (Normal)
Medium (Rain)
High (Snow) *
* - BGIII-C
COM
SAF
STALL
12
11
15, 17
9
4
5
Grey
Blue
Purple
White
White
Red
4 White
3 Violet
5 Red
3, 6, 8
10
4
US and Canada:
1-866-249-7937
Canada:
1-866-836-1863
Northeast:
1-866-836-1863
1ST ROW OF IR
THRESHOLD
3
2ND ROW OF IR
3RD ROW OF IR
4TH ROW OF IR
6
9
VALUE
BUTTON
0 (min)
9 (max)
0 (min)
9 (max)
1
2
1
2
3 *
SWING
STALL COM
ACT
16, 18
HUNTER
ACT
13
KM K
Green
STANLEY L
Grey
Orange
STANLEY M/P
Red
STANLEY 521
5 Red
TB4-5
3, 6, 8
TORMAX TDA
Pattern Depth
1: Deep (Threshold ON)
2: Medium (Threshold ON - OPEN)
3: Limited (Threshold ON)
4: Deep (Threshold OFF)
5: Medium (Threshold OFF - CLOSED)
6: Limited (Threshold OFF)
1
3
5
PARAMETER
INTERFACE
New Style
Old Style (LO21, B, K,
P, S, U, LO-LINX, MC15)
SETUP / WAND
Door Closed = 1
Door Open = 2
Restore to Default
HOLD TIME
0 = 0.5 sec
9 = 9 sec
FREQUENCY
Normal Mode; Low
Normal Mode; High
Quiet Mode; Low
Quiet Mode; High
COM
SAF
RTN
SAF 1
White
Red
Yellow
Red
2
1, 8
7
TB4-8
TB4-4
2
1, 3, 6, 8
8 & 9
Southeast:
1-800-407-4545
Midwest:
1-888-308-8843
West:
1-888-419-2564
2
4
6
VALUE
1
2
1
2
9
0 (min)
9 (max)
1
2
3
4
STILL
STALL COM
SAF 2
RTN
Yellow
White
Yellow
Blue
1, 8
7
TB4-10
TB4-9
1, 3, 6, 8
7
75.5362.01 20090210