1-3 Other Component Specifications
(A) Indoor Unit
MODEL No.
Power Transformer
Rated
Coil resistance
(Ambient temprature 77 °F)
Thermistor cut off temperature
Thermistor (Coil sensor)
Coil resistance
Thermistor (Room or coil sensor)
Coil resistance
1
2
3
4
5
6
Primary
Secondary
BRN - BRN : 14 V / 0.55 A, RED - RED : 14 V / 0.3 A
Capacity
WHT - WHT
BRN - BRN
°F
14 °F : 23.7
kΩ
23 °F : 18.8
32 °F : 15.0
41 °F : 12.1
50 °F : 9.7
32 °F : 16.5
kΩ
41 °F : 12.8
50 °F : 10.0
68 °F : 6.3
86 °F : 4.0
UH3672R
ATR – IIK244B
AC 220 V, 60 Hz
: 48.0
,
RED - RED
:
0.45
,
ORG - ORG
277
PBC - 41E - S36
,
,
,
,
,
KTEC - 35 - S85
,
,
,
,
,
DATA SUBJECT TO CHANGE WITHOUT NOTICE
I-56
1. Specifications
:
0.89
:
2.05
59 °F : 8.0
68 °F : 6.5
86 °F : 4.4
104 °F : 3.1
113 °F : 2.6
104 °F : 2.7
113 °F : 2.2
122 °F : 1.8
131 °F : 1.5
SM831148