Dry Operation - Sanyo C2462R Technical Data & Service Manual

Split system air conditioner
Hide thumbs Also See for C2462R:
Table of Contents

Advertisement

11. PROCESSES AND FUNCTIONS
(2) Dry Operation (Dehumidification)
Dry operation uses the ability of the cooling cycle to remove moisture from the air, but by
running at low level to dehumidify without greatly reducing the room temperature. The air
conditioner repeats the cycle of turning ON and OFF automatically as shown in the chart
below according to the room temperature.
Room temp.
T + 4 F
Set temp. T F
T – 2 F
Room temp. 59 F
NOTE
Intermittent ventilation occurs by switching the indoor fan speed between L
Dry operation does not occur when the room temperature is under 59 F, which is the monitor zone.
When the compressor stops, the indoor fan stops as well.
Cooling operation
Dry A zone
Compressor :
Continuous operation
FMI (indoor fan) :
L (low speed) / LL (very low speed) intermittent ventilation
only while the compressor is ON.
Dry B zone
Compressor :
Intermittent operation (ON for 3 minutes and OFF for 9 minutes)
FMI (indoor fan) :
L (low speed) / LL (very low speed) intermittent ventilation
only while the compressor is ON.
Monitor zone
Both the indoor and outdoor units stop.
– 36 –
2213_M_S
Fig. 12
LL.
SM830092

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl2462rKs2462r

Table of Contents