Download Print this page

Sanyo 09KS51 Submittal Sheet page 2

Indoor/outdoor wall mount air conditioner

Advertisement

SUBMITTAL SHEET
SYSTEM
09KLS51
WALL MOUNT LOW AMBIENT AIR CONDITIONER
GENERAL DATA (AT 115V)
POWER
V/PH/HZ
Circuit Ampacity, Min. (A)
Fuse size, Max.
(A)
COMPRESSOR
No. used
R.L. Amps - L.R. Amps (A)
Crankcase Heater
OUTDOOR FAN - TYPE
Dia. (in.) - No. used
Type Drive - No. speeds
No. Poles - RPM (High)
No. Motors - W
CFM (High)
F.L. Amps. (A)
OUTDOOR COIL - TYPE
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
INDOOR FAN - TYPE
Dia. & Length (in.) - No. used
No. speeds
No. Poles -RPM (High)
No. Motors - W
CFM (HI/MED/LOW)
F.L. Amps (A)
INDOOR COIL - TYPE
Fin Type - Pipe type
Rows - F.P.I.
Face Area (sq. ft.)
Tube Size (mm)
Drain Connection Size (in.)
REFRIGERANT
Lbs. - R22 (O.D. Unit)
Control
Connection
Line Length, Max (ft.)
Lift difference, Max (ft.)
Line Size - in. O.D. Discharge
Line Size - in. O.D. Suction
DIMENSIONS (in.)
H
Indoor Unit
-Uncrated 10-5/8
-Crated
9-13/16 x 33-21/32 x 13-5/16
Outdoor Unit -Uncrated 21-1/4
-Crated
23-31/32 x 38-5/8
WEIGHT
INDOOR
Net
(lbs.)
17.6
Shipping (lbs.)
22.0
Shipping Volume(cu.ft.)
2.51
INDOOR/OUTDOOR
KS0951/CL0951
115/1/60
15
15
Rotary-Hermetic
1
7.7-49
20W
Propeller
16-17/32 - 1
Direct - 1
6 - 600
1 - 21.6
1020
0.7
Aluminum Fin & Copper Pipe
Slit Plate - Inner Flat
1 - 18
4.2
3/8
Cross-flow
3-3/4 & 24-9/32-1
3 & Auto
4-1,200
1 - 18.2
270/240/220
0.4
Alminum Fin & Copper Pipe
Slit Plate - Inner Flat
2 - 18
1.4
7
23/32
R22
1.28
Capillary Tube
Flare
50
23
1/4
3/8
x
W
x
D
x 31-11/16 x 6-31/32
x 31-1/2
x 11-13/32
x 16-3/16
OUTDOOR
66.1
75.0
8.67
AIRCONDITIONING PRODUCTS
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (115V)
COOLING
Total Capacity
(BTU/H)
Sensible Capacity (BTU/H)
Latent Capacity
(BTU/H)
SEER
Dehumidification
(Pints/H)
Amps
(A)
Power Inputs
(W)
Outdoor Sound Rating (bels)
FEATURE
Controls
Remote Controller
Temperature Control
Timer
ON/OFF,
Night Setback
Air Louver
(Horizontal)
(Vertical)
Power Failure Automatic Restart
Self Diagnosis
OPTION
Refrigerant Line Set
Air Clean-Filter
Fresh Air Intake
Central Remote ON-OFF Control
Airduct Extension
Indoor Frame Extension
Condensate Drain Pump
Non-Removable Remo-con Bracket
OPERATING RANGE
Cooling
Indoor Air
Intake Temp.
Maximum 95 F DB/71 F WB
Minimum
67 F DB/57 F WB
CERTIFICATION
SS09KLS51-2
9,000
6,420
2,580
10.0
2.0
8.8
900
7.0
Microprocessor
LCD Wireless type
IC Thermostat
ProgramTimer
Built-In
Manual
Auto
Built-In
N/A
AP0905BH
(15 ft)
AP0907BH
(20 ft)
AP0910BH
(30 ft)
STK-ARF4B
N/A
Available
N/A
N/A
Optional
Optional
Outdoor Air
Intake Temp.
115 F DB
0 F DB
09KLS51

Advertisement

loading

This manual is also suitable for:

Ks0951C095109kls51Cl0951Ks1251C1251 ... Show all