note: Always operate the Breather Box® in the upright position. Failure to comply may result in one or all
of the following:
1) Auto drains will not function properly. This may result in the contamination of the CO monitor and cause
oil/water to be passed through the respirator hose and into the worker's mask.
2) Auto drains may become clogged.
3) Filters may accumulate moisture and/or contamination.
SteP 1)
Secure a primary air source of sufficient air flow and discharge pressure. The
number and type of respirators being used determines the flow rate and pressure
required.
SteP 2)
Check airline monitor for fresh 9 volt batteries and turn unit on. Connect the
remote signal cable, 115 VAC plug, and air sample hose to the monitor. Place the
"ON/OFF/TEST" switch to the "ON" position. Allow 30 seconds for the readout to
stabilize. If a reading other than "00" is displayed, calibration of the monitor may
be necessary. See calibration procedure.
SteP 3)
Connect the extension cord to a 115 VAC receptacle.
Note: The CO monitor can run off the 9 volt batteries if AC power is not available.
SteP 4)
Remove the cover plate on the right side of panel to access the 115 VAC remote alarm connections.
Connections are as follows: Black - Line, White - Neutral, and Green - Ground
SteP 5)
Close the flowmeter by turning the control knob fully clockwise. Do not over-tighten.