Download Print this page

Omron V680-HAM42-FRT Instruction Sheet page 2

Fl remote id
Hide thumbs Also See for V680-HAM42-FRT:

Advertisement

V680-HAM42-FRT
Model
FL Remote ID
INSTRUCTION SHEET
NOTICE:
This product meets CISPR11 class A. The intended use of
this product is in an industrial environment only.
TRACEABILITY INFORMATION:
Importer in EU :
Manufacturer:
Omron Europe B.V.
Omron Corporation,
Wegalaan 67-69
Shiokoji Horikawa, Shimogyo-ku,
2132 JD Hoofddorp,
Kyoto 600-8530 JAPAN
The Netherlands
2007
© OMRON Corporation
All Rights Reserved.
SAFETY PRECAUTIONS
Meaning of Signal Words
Indicates a potentially hazardous situation
which, if not avoided, could result in death
or serious injury.
WARNING
Additionally,there may be severe property
damage.
Alert statements
WARNING
This product is not designed or rated for ensuring
safety of persons.
Do not use it for such purposes.
PRECAUTION FOR SAFE USE
Observe the following precautions to ensure safe usage of the product.
1. Do not use the product in environments subject to inflammable, explosive,
or corrosive gas.
2. Do not disassemble, repair, or modify the product in any way.
3. Tighten the mounting screws securely.
4. Because a cable has a locking mechanism, make sure that it has been
locked before using the cable.
5. Confirm that the DC power supply is within the rated power supply
voltage (24 VDC +10%/-15%) before using it.
6. Do not reverse polarity when connecting the power supply.
7. Do not allow water to enter or insert wire in the gaps of the case. Fire or
electric shock may result.
8. Provide enough space around the controller for ventilation.
9. Avoid setting up the unit near a highly heat-generating device
(such as heater, transformer and large-capacity resistor).
10. Always turn OFF the power supply to the product before attaching or
removing the Antenna.
11. If you suspect that anything is wrong with the product at any time, stop
using it immediately, turn OFF the power supply, and consult with your
OMRON representative.
12. When disposing of the product, dispose of it as industrial waste.
13. Do not use thinners, benzenes, acetones and kerosenes for cleaning.
14. Communications performance may be reduced due to mutual interference
if more than one Read/Write Antenna is installed in the same vicinity.
Refer to the Operating Manual (Cat.No.Z268-E1) and confirm that there is
no mutual interference between Read/Write Antennas.
PRECAUTION FOR CORRECT USE
1. Installation Location
Do not install and storage the product in the follwing locations:
・ Locations subject to corrosive gases, dust, dirt, metal powder, or salt.
・ Locations where the specified ambient temperature range is exceeded.
・ Locations subject to extreme temperature changes that may result in
condensation.
・ Locations where the specified ambient humidity range is exceeded.
・ Locations where the product would be directly subjected to vibration or
shock exceeding specifications.
・ Locations subject to contact with water, oil, or chemicals
2. Installation
・ The product uses the 13.56MHz frequency band to communicate with
Tags. Some devices, such as some tranceivers, mortors, inverters, and
switch mode power supplies, generate electromagnetic waves (i.e., noise)
that can affect communications with the Tags. If any of these devices are
nearby, communications with Tags may be affected or Tags may be
destroyed, If the product is to be used near such devices, check the
effects on communications before using the product.
・ To minimize the general influence of noise, follow the following
precautions:
(1)Ground the earth terminal of this product and any metallic material
located around the product to 100 Ω or less.
(2)Keep product wiring away from high voltage or heavy current.
・ Attach the accompanying ferrite core (Type:ZCAT2032-0930 made by
TDK Corp.) around the cables that are connected with the power and
grounding terminals.
・ The product does not provide a water-proof structure. Do not use it where
mists are present.
General specifications
Characteristic
Specification
24 VDC (-15% to 10%)
Supply voltage
Power consumption Up to 6W
Ambient operating
-10 to 55℃(no freezing)
temperature
Ambient operating
25 to 85%(no dew condensation)
humidity
Ambient storage
-25 to 65℃(no freezing)
temperature
Ambient storage
25 to 85%(no dew condensation)
humidity
Insulation resistans 20MΩ min. (with 500V DC mega)
Between terminals (except for grand) and casing
Between terminals (except for grand) and grand
Withstand voltage 1,000V AC, 50/60 Hz, 1min
Between terminals (except for grand) and casing
500V AC, 50/60 Hz, 1min
Between terminals (except for grand) and grand
Vibration resistanse Mechanical durability: 10 to 150 Hz, double amplitude: 0.2 mm
with 10 sweep of 8 min each in 3 directions
2
Shock resistance
Mechanical durability: 150m/s
, 3times each in 6 directions
×
×
Dimensions
65
65
65 mm (excluding protruding parts)
Degree of protection Panel-mounting (conforms to IP20)
Material
PC/ABS resin
Weight
Approx. 150 g
Mounting method DIN Track
Frequency
13,56MHz
Radiated magnetic
maximum 20 dBμA/m at 10 meters
field strength
Name and functions
(1)Status indicator
DEV:Device status
RMT:Remote status
T/R:Transmission status
NORMAL/ERROR:Communication status
(2)Data indicator (2colored LED)
DATA:DATA code (Green)
ERC:Error code (Red)
(3)Mode Switch (Rotary switch3)
regulates function mode
(4)Node Address Switch (rotary switch1,2)
node address setting (01∼64)
(5)FL remote connector
Connect to the FL Remote Master Unit
(6)Power terminal
Use wire size of AWG 12-22 with strip length of
10 mm, and use an isolated 24VDC power source
for supply circuit. Recommended source is
S8VS-03024 (OMRON).
(7)Antenna connector
(1)Status indicator
For connecting model V680-HS63-SP
DEV(Device status indication)
Status
Mean
Green
Normal
Red
Serious malfunction
Red(blinking)
Slight malfunction
Unlit
Power off
RMT(Remote status indication)
Status
Mean
Green
Connected to network/Transferring FL Remote IO
Green(blinking)
Connected to network/No transferring FL Remote IO
Green and Red(blinking) Connected to network/Setting error
Red
Duplicate node address
Red(blinking)
Not connected to network
Unlit
Not connected to network
T/R
Status
Mean
Yellow
Communicating to RF Tag
Unlit
Standby
NORMAL/ERROR
Status
Mean
Green
Communication nomal finish
Red
Communication error
Unlit
standby
(2)Data indicator
DATA/ERC
Status
Mean
Green
Indicate communicating data contents
Red
Indicate error code
Unlit
standby
Error code
LED
Description
Bit 0
Cannot detect RF tag in trigger mode.
Bit 1
Cannot communicate with RF tag in trigger mode.
Bit 2
The address outside the memory area of RF tag was specified.
The protected memory area of RF tag was specified.
Bit 3
Bit 4
The data could not be written in RF tag.
Bit 5
The RF tag of off the subject was used.
Bit 6
The RF tag of off the subject was used.
Bit 0 and Bit4
The mistake is found in the instruction of the excution command.
or the FL remote ID cannot recieve the execution specification command.
Bit7 to Bit 0
The setting of the mode switch is abnormal.
Bit7 to Bit 0
FL remote ID cannot work.
(3)Mode Switch
No.
Name
Mean
0
Trigger mode When the trigger signal is input from the plc, FL REMOTE ID begins the
communication with the ID tag, and outputs the communication result to the plc.
1
Auto mode When the ID tag approaches the antenna front, FL REMOTE ID begins the
communication with the ID tag, and outputs the communication result to the plc.
2
Test mode
FL REMOTE ID repeatedly executes the ID Tag read of 4 bytes from
00 addresses without the control from the plc
3
Noise mode The noise environment in the antenna surroundings can be measured while
disconnected from the Master Unit.
4
E-paper label For e-paper label developed by TOPPAN FORMS co.,ltd. the data can be read
mode
from and written to displayed information can be rewritten.
other
mode error
Dimensions
(Unit: mm)
STATUS INDICATOR
DATA INDICATOR
65
20
10
5
5
5
NODE ADDRESS
MODE SWITCH
SWITCH
12
6
18
ANTENNA CONNECTOR
17.8
21.5
FL REMOTE
CONNECTOR
5.06
POWER TERMINAL
Suitability for Use
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer's application or use of the Product. At Buyer's request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer's application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
OMRON Corporation
Industrial Automation Company
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
s
D
Oct, 2014
5

Advertisement