SECTION D - MAINTENANCE

D1 - Daily: 1) Shut down Fryer as per Section C5. Drain completely (using Drain Pipe Extension) into clean suitable container or filter pump.
2) Detach Basket Hanger Bracket, remove screen and wipe clean with cloth.
3) Flush out any remaining sediment in tank using some hot oil. Wipe off and clean fry kettle.
4) Close Drain Valve and strain shortening back into fryer using several layers of cheese cloth or filtering thru an oil pump equipped with a
Micro-Flo filtering system. Replace Crumb Screen, Basket Hanger Bracket, detach Drain Nipple and Fryer is ready for next operation.
D2 - Weekly: Repeat daily maintenance procedure up to point (4). Close Drain Valve and clean vessel thoroughly with a deep fat fryer cleaning
compound and hot water. Drain and rinse thoroughly. Wipe dry with a clean cloth. Clean exterior stainless steel surfaces of body with stainless steel
cleaner. Do not use abrasive cleaners or steel wool.
D3 - Periodic checks: Temperature of frying compound. Set thermostat knob to 350° F. Place a fryer thermometer in fat (1 1/2 inches) and
observe reading when burner goes out. Compare reading. If the temperatures do not coincide within 5° F, have qualified service person calibrate
thermostat. See Adjustment Procedure, Section E below. Clean unit and dirt off air shutters and main burners. After long period burners and pilot
should be cleaned for proper ignition and burner flame efficiency.
OUTSIDE SERVICE: Should you require help contact the factory, your factory representative, or your local service company.
2 FLUE BOX ASSEMBLY
3 BASKET HANGER
4 BASKET SUPPORT FASTENER
5 FRY TANK C.R.S.
7 FRY BASKET
8 CRUMB SCREEN
9 BULB CLAMP
10 FRONT FASCIA ASSEMBLY
11 BURNER SUPPORT ASSEMBLY
12 BURNER TUBE RAFFLE
13 DOOR HANDLE
14 FRONT DOOR ASSEMBLY
15 GAS BURNER
16 AIR BURNER SHUTTER
17 AIR SHUTTER CLAMP
18 NUT RETAINER
21 BRASS PLUG
20 GAS ORIFICE (NATURAL)
GAS ORIFICE (PROPANE)
19 BURNER MANIFOLD
22 DRAIN VALVE
23 DRAIN PIPE
24 THERMOPILE
25 PILOT BURNER ASS'Y (NAT.)
PILOT BURNER ASS'Y (PROP.)
26 MAGNETIC CATCH
27 THERMOSTAT KNOB
Added details: Item #43 Flame Shield (For one tube) T177A
Item #44 Flame Shield (For two tubes) T176A
PARTS LIST FMP 403
T849Q
28
THERMOSTAT BRACKET
T536A
29
THERM. HARNESS ASS'Y
P281A
30
HI-LIM WIRE ASS'Y
T847A
31
THERMOSTAT
V174A
32
HI-LIMIT CONTROL
V182A
33
¾" UNION ELBOW
U567A
34
GAS CONTROL (NAT.)
U647A
GAS CONTROL (PROP.)
T632Q
35
½" UNION ELBOW
U617Q
36
DOOR HINGE
M028A
37
½" GAS INLET PIPE
T865A
38
DRAIN PIPE HOLDER
G224A
39
CABINET ASSEMBLY
F167A
40
ADJUSTABLE LEG (1)
U574A
P284A
K044A
F251A
F252A
OPTIONAL: QUICK DISCONNECT
F010A
FLEXIBLE HOSES
D048A
J062A
¾" x 36" (167,000 BTU/HR @ 0 - 5" W.C.)
F178A
¾" x 36" W. THERM. SHUT-OFF
F179Q
¾" x 48" (156,000 BTU/HR @ 0 - 5" W.C.)
F180Q
¾" x 48" W. THERM. SHUT-OFF
U008A
ADJUSTS UP TO 48"
M099A
6
U572V
C946Q
C945Q
L345A
L346A
K158A
L347A
L348A
K204A
U579V
J073A
U581V
T678Q
M219A
F189A
F191A
F190A
F192A
P288Q

Advertisement