Technical Specificaton; Types, Cells & Rated Capacity - Primepower Workshop charger Manual

12/70;24/60;12/100
Table of Contents

Advertisement

Available languages

Available languages

TECHNICAL SPECIFICATON

Dimensions (L x W x H)
Weight
Ambient temperature
Mains voltage
Rated current 12V
Rated current 24V
Fluctuation
Charging voltage AGM
Charging voltage Standard
Maintenance charging
Frequency on supply voltage (AC)
Standby current from the battery
Recommended mains fuses
Mains cables
Battery cables 12V 100A
Battery cables 12V/24V 60A
Protection
IP Code
Housing
General
TYPES, CELLS & RATED CAPACITY
CHARGER
Workshop Charger 12/24V 70A
Workshop Charger 12V 120A
294 x 135 x 94.5 mm
2,2 Kg (without cables)
o
– 20
C > +50
90-270VAC – 0-400Hz
120A resp. 70A (Depending on model)
60A
< 3%
14.4 VDC for 12V batteries
14.7 VDC for 12V batteries
13.8 VDC for 12V batteries
45 Hz to 65 Hz
< 2 mA
C10
Rubber cable with Neutrik coupler & Schuko plug. 1,5m
2
2 x 25mm
2
2 x 25mm
2
2 x 10mm
2
2 x 10mm
Class I, grounded
IP21
Aluminum
Protection against wrong polarity and short circuits. CE-
certified in accordance with valid EN-standards.
BATTERY TYPE
Lead acid batteries
Lead acid batteries
o
C
28.8 VDC for 24V batteries
29.4 VDC for 24V batteries
27.6 VDC for 24V batteries
2m with terminal clamps 200A (standard)
5m with terminal clamps 200A (optional)
2m with terminal clamps 200A (standard)
5m with terminal clamps 200A (optional)
NUMBER OF CELLS
6/12
6
RATED CAPACITY
40-1000Ah
50-1500Ah

Advertisement

Table of Contents
loading

Table of Contents