12.

Option devices

12.1 About option devices

Option devices of this unit are showed below. Please reference to manual of option devices.
Product name
Extention
Energy Measuring Unit
unit
Extension for the systems with
the same voltage
Energy Measuring Unit
Extension for the systems with
the different voltage
Energy Measuring Unit Energy
Measuring Extension Model
for Pulse Input
Energy Measuring Unit Energy
Measuring Extension Model
for Analog Input
Option
CC-Link Communication Unit
unit
for Energy Measuring Unit
Logging Unit
for Energy Measuring Unit
CC-Link IE Field Basic
Communication Unit for
Energy Measuring Unit
Small-size Display Unit
for Energy Measuring Unit
Peripheral
Current sensor
equipment
Split type 5A current sensor
cable
Model
EMU4-A2
EMU4-VA2
EMU4-PX4
EMU4-AX4
EMU4-CM-C
EMU4-LM
EMU4-CM-CIFB
EMU4-D65
EMU-CT50
EMU-CT50-A
EMU-CT100
EMU-CT100-A
EMU-CT250
EMU-CT250-A
EMU-CT400
EMU-CT400-A
EMU-CT600
EMU-CT600-A
EMU-CT5-A
EMU2-CT5
EMU2-CT5-4W
EMU2-CB-Q5A
EMU2-CB-Q5A-4W
EMU2-CB-T1M
EMU2-CB-T5M
EMU2-CB-T10M
EMU2-CB-T20M
EMU2-CB-T1MS
EMU2-CB-T5MS
EMU2-CB-T10MS
43
Note
You can monitor Multi-circuit in same voltage
system to extension main unit. Up to 3 units can be
connected in energy measure unit.
You can monitor Multi-circuit in different voltage
system to extension main unit. Up to 3 units can be
connected in energy measure unit.
You can monitor at most 4 circuits of pulse/a contact
input system to extension main unit.
When data exceeded the established upper limit
value, indication of LEDs and contact output are
performed.
You can monitor at most 4 circuits of analog input
(0-+5V/0-+20mA) system to extension main unit.
When data exceeded the set upper limit value,
indication of LEDs and contact output are
performed.
You can use CC-Link communication by connecting
main unit.
You can log the measured data by connecting
main unit.
You can use CC-Link IE Field Network
Basic Communication by connecting main unit.
You can display the measured data and use for
setup.
50A split type
100A split type
250A split type
400A split type
600A split type
5A split type
5A split type (1P2W, 1P3W, 3P3W)
5A split type (3P4W)
Connect to current input terminal for 1P2W,
1P3W, 3P3W.
Connect to current input terminal for 3P4W.
Extension cable(Standard type) 1m
Extension cable(Standard type) 5m
Extension cable(Standard type) 10m
Extension cable(Standard type) 20m
Extension cable(Separate type) 1m
Extension cable(Separate type) 5m
Extension cable(Separate type) 10m