8.
Device operation
8.1 Resolution of measuring data
The resolution of measuring data is determined as follows according to the rating settings (phase wire system, primary current and
primary voltage).
■Voltage, harmonic voltage RMS
Primary voltage setting
less than 300V
300V ~ 3000V
3000V ~
■Harmonic voltage/ Harmonic voltage distortion ratio,
1 decimal places:0.1%
■power, power demand, reactive power, apparent power
Total load power
less than 12kW
12 kW ~ 120 kW
120 kW ~ 1200 kW
1200 kW ~ 12000 kW
12000 kW ~ 120000 kW
120000kW ~
■Electric energy(expansion), reactive energy(expansion)
Total load power
less than 12kW
12 kW o ~ 120 kW
120 kW ~ 1200 kW
1200 kW ~ 12000 kW
12000 kW ~ 120000 kW
120000kW ~
Note: Extended electric energy is the data of lower three digits
more than electric energy data.
response data is the same as the amount of electric energy
data.
■Electric energy converted value
The Unit depends on setting value.
Total load power
less than 12kW
12 kW ~ 120 kW
120 kW o ~ 1200 kW
1200 kW ~ 12000 kW
12000 kW ~ 120000 kW
120000kW ~ 1200000kW
1200000kW ~
■Pulse converted value
The Unit depends on setting value.
Total load power
0.001 ~ 0.01
0.01 ~ 0.1
0.1 ~ 1.0
1 ~ 10
10 ~ 100
100 ~ 1000
1000 ~
Resolution
Unit
1 decimal places
V
Integer
×10
Resolution
Unit
3 decimal places
2 decimal places
kW
1 decimal places
kvar
Integer
×10
×100
Resolution
Unit
5 decimal places
4 decimal places
3 decimal places
kWh
kvarh
2 decimal places
1 decimal places
Integer
The number of digits of
Resolution
2 decimal places
1 decimal places
Integer
×10
×100
×1000
×10000
Resolution
3 decimal places
2 decimal places
1 decimal places
Integer
×10
×100
×1000
33
■Current, current demand harmonic current
Primary current setting
less than 40A
40A ~ 400A
400A ~ 4000A
4000A ~
■Power factor
1 decimal places:0.1
■Electric energy, reactive energy
Total load power
less than 12kW
12 kW ~ 120 kW
120 kW ~ 1200 kW
1200 kW ~ 12000 kW
12000 kW ~ 120000 kW
120000kW ~
・The image of the Extended electric energy
In the case measuring device has "12345.6789" as internal data.
Electric energy data:"123456"
12345.6789
Extended electric energy data:"456789"
Resolution
Unit
3 decimal places
2 decimal places
A
1 decimal places
Integer
■Frequency
1 decimal places:0.1Hz
Resolution
Unit
2 decimal places
1 decimal places
kWh
Integer
kvarh
×10
×100
×1000