  • Page 1 Hardware Description and Installation Manual...
  • Page 2 Copyright Laws. LG-Ericsson reserves the right to make changes in specifications at any time without notice. The information furnished by LG-Ericsson in this material is believed to be accurate and reliable, but is not warranted to be true in all cases.
  • Page 3 Hardware Description and Installation Manual Issue 2 July, 2010 This device complies with part 15 /RSS-GEN of the FCC/IC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.
  • Page 4: Ipldk-60 Hardware Description And Installation Manual Issue

    Hardware Description and Installation Manual Issue 2 July, 2010 Revision History ISSUE DATE Contents of Changes 2007.01 Initial Release 2009.02 Added PRHB8 2010.07 Added EMU2, CKB316, LDP-7200 series, LIP-7000 & 8000 series IP phones General edits 2011.06 Added GDC-600BE...
  • Page 5: Table Of Contents

    Hardware Description and Installation Manual Issue 2 July, 2010 Table of Contents 1 INTRODUCTION................... 1 1.1 Important Safety Instructions ..............1 1.1.1 Safety Requirements ....................1 1.2 Precaution ..................... 2 1.2.1 Caution ........................2 1.2.2 Disposal of Old Appliance ................... 2 1.3 Manual Usage ....................
  • Page 6 Hardware Description and Installation Manual Issue 2 July, 2010 4 BOARD INSTALLATION ..............28 4.1 Installation of the Boards ................28 4.2 Main Board Unit (MBU) ................29 4.2.1 Modular Jack (MJ1 – MJ3) Pin Assignment ............. 31 4.2.2 Switches and LED Indications .................. 32 4.3 Expansion Main Board Unit (EMBU) ............
  • Page 7 Hardware Description and Installation Manual Issue 2 July, 2010 7 STARTING THE IPLDK-60 ..............71 7.1 Before Starting the ipLDK-60 System ............71 7.2 Basic Programming ................... 71 7.2.1 DKT Programming ....................71 7.2.2 Entering the Programming Mode ................73 7.2.3 Pre-Programming .....................
  • Page 8: Introduction

    Hardware Description and Installation Manual Issue 2 INTRODUCTION July, 2010 1.1 Important Safety Instructions 1.1.1 Safety Requirements When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and other personal injury, including the following: Please read and understand all instructions.
  • Page 9: Precaution

    1.2 Precaution Keep the system away from heating appliances and electrical noise generating devices such as florescent lamps, motors and televisions. These noise sources can interfere with the performance of the ipLDK-60 System. This system should be kept free of dust, moisture, high temperature (more than 40 degrees) and vibration, and should not be exposed to direct sunlight.
  • Page 10: Manual Usage

    1.3 Manual Usage This document provides general information covering the hardware description and installation of the ipLDK-60 System. While every effort has been taken to ensure the accuracy of this information LG-Ericsson makes no warranty of accuracy or interpretations thereof.
  • Page 11: Abbreviations

    Hardware Description and Installation Manual Issue 2 INTRODUCTION July, 2010 1.4 Abbreviations AAFU: Auto Attendant Function Unit JTAG: Joint Test Action Group AC: Alternating Current KSU: Key Service Unit ACD: Automatic Call Distributor LAN: Local Area Network ADPCM: Adaptive Differential Pulse Code Max.: Maximum...
  • Page 12: System Overview

    Hardware Description and Installation Manual Issue 2 SYSTEM OVERVIEW July, 2010 2.1 ipLDK-60 System Highlights Features of the ipLDK-60 System include: Flexible architecture Simple system structure Powerful PC application via LAN, Modem, RS-232C Enhanced voice features Easy installation & efficient system management - Remote admin &...
  • Page 13: System Connection Diagram

    Hardware Description and Installation Manual Issue 2 SYSTEM OVERVIEW July, 2010 2.1.1 System Connection Diagram The following Figure shows the components that make up the ipLDK-60 System: FIGURE 2.1.1 SYSTEM CONNECTION DIAGRAM...
  • Page 14: System Components

    Hardware Description and Installation Manual Issue 2 SYSTEM OVERVIEW July, 2010 2.2 System Components BASIC KSU ITEM OPTION DESCRIPTION BOARD Key Service Unit Power Supply Unit Main Board Main Board Unit (3CO, 1DKT and 7 Hybrid) CO and Extension...
  • Page 15 Hardware Description and Installation Manual Issue 2 SYSTEM OVERVIEW July, 2010 EXPANSION KSU Item Option Board Description Key Service Unit Power Supply Unit Main Board EMBU Expansion Main Board Unit (3 CO and 8 Hybrid) CO and Extension CO Line and DKT/SLT interface Boards...
  • Page 16: Specifications

    Hardware Description and Installation Manual Issue 2 SYSTEM OVERVIEW July, 2010 2.3 Specifications 2.3.1 General Specifications Item Description Specification ARM7 TDMI core(32bit, 50MHz) Switching Device Custom Mixed-Signal ASIC Device Memory Back-up Duration 7years AC Voltage Input 100~240 +/- 10% Volt AC @47-63Hz...
  • Page 17: System Capacity

    Hardware Description and Installation Manual Issue 2 SYSTEM OVERVIEW July, 2010 2.3.2 System Capacity Description Capacity/Board Total Time Slots CO Line Ports 3/MBU, 3/EMBU, 3/(CHB308, CKB316, Max. 36 CSB316), 8/VOIB, 30/E1HB8 Max Direct Station (DKT, SLT, 8/MBU, 8/EMBU, 16/EMBU2, Max.
  • Page 18: Wireless Terminal Specification

    Hardware Description and Installation Manual Issue 2 SYSTEM OVERVIEW July, 2010 2.3.4 Wireless Terminal specification Item Specification Max. Transmission Power 250mW Modulation Method GFSK Frequency Band 1,880MHz ~ 1,900MHz...
  • Page 19: Ksu Installation

    Anti-static precautions should be taken during installation. 3.1.2 Installation precautions The ipLDK-60 System is designed for wall mounting or a free–standing rack. Avoid installing in the following places: In direct sunlight and hot, cold, or humid places. Temperature range = 0 to 40 Places where shocks or vibrations are frequent or strong.
  • Page 20: Ksu Installation

    Hardware Description and Installation Manual Issue 2 KSU INSTALLATION July, 2010 3.2 KSU Installation 3.2.1 Unpacking Open the box and verify that the items shown in Figure 3.2.1 are included with the Basic KSU: FIGURE 3.2.1 CARTON CONTENTS...
  • Page 21: Ksu Exterior And Dimension

    Hardware Description and Installation Manual Issue 2 KSU INSTALLATION July, 2010 3.2.2 KSU Exterior and Dimension Figure 3.2.2 shows the exterior and dimensions of the KSU in milli-meters. FIGURE 3.2.2 KSU EXTERIOR AND DIMENSION...
  • Page 22: Opening And Closing The

    Hardware Description and Installation Manual Issue 2 KSU INSTALLATION July, 2010 3.2.3 Opening and Closing the Front Cover 3.2.3.1 Opening the Front Cover 1. Open the Cord cover and turn the screws counter-clockwise to loosen as shown in Figure 3.2.3.1.
  • Page 23 3. Turn the screws clockwise to tighten and close the Wiring Tray cover as in the Figure. FIGURE 3.2.3.2 CLOSING THE FRONT COVER Note ° Prior to operation, the front cover of the ipLDK-60 should be closed and the screws tightened.
  • Page 24: Power Supply Unit Installation

    Before installation, assure that the AC plug is not connected to an AC outlet. The PSU is located at the left in the KSU and is pre-installed in the ipLDK-60 KSU. The PSU provides three DC voltage power sources to MBU through the 7-pin connector, CN7.
  • Page 25: Frame Ground Connection

    July, 2010 3.2.5 Frame Ground Connection It is very important that the frame of the ipLDK-60 System is grounded. Proper grounding reduces RF noise and reduces the potential damage from Lightning strikes. 1. Turn the grounding screw counter clockwise to loosen, as shown in Figure 3.2.5.
  • Page 26: External Backup Battery Installation

    July, 2010 3.2.6 External Backup Battery Installation In case of power failure, the external backup batteries automatically maintain uninterrupted power for the ipLDK-60 System. The external batteries must provide 24V DC; this is generally accomplished by connecting two 12V batteries in a series arrangement as shown. The cable used to connect the battery is supplied with the KSU.
  • Page 27: Ksu Mounting

    Hardware Description and Installation Manual Issue 2 KSU INSTALLATION July, 2010 3.2.7 KSU Mounting 3.2.7.1 Wall Mounting 1. Install three (3) anchor plugs in the wall using the mounting template included for accurate placement (Figure 3.2.7.1A). 2. Attach the mounting template using the three (3) screws and anchors included.
  • Page 28: Ipldk-60 Hardware Description And Installation Manual Issue

    Hardware Description and Installation Manual Issue 2 KSU INSTALLATION July, 2010 FIGURE 3.2.7.1B KSU WALL MOUNTING Note ° Be careful not to drop the KSU.

Table of Contents