4-2-1. Quick Test Mode
Water Valv e Test:
Water Valve Test:
1. To enter the Water Valve Test, press theTemp Key while
model information is being display ed during the Quic k
1. To enter the Water Valve Test, press the Temp Key while model information is
Test Mode.
being displayed during the Quick Test Mode.
2. Each time the Temp Key is pressed, itwill cycle through
the operations on the left flowchart.
2. Each time the Temp Key is pressed, it will cycle through the operations on the
But, WF306L A W(F3) and WF306BHW(F8b) do
left flow chart. But, WF306LAW(F3) and WF306BHW(F8b) do not have the
the prewater valve. So, it will skip Pre Water Va lve On an d
pre water valve. So, it will skip Pre Water Valve On and jump to Cold Water
jump to Cold Water Valve On.
Valve On.
3. If the Temp Key is pressed duringAll Water Valve OFF,
the machinewill return to the beginning as shown
3. If the Temp Key is pressed during All Water Valve OFF, the machine will return
in the flowchart.
to the beginning as shown in the flow chart.
4. The door needs to besecured for the Water Valve to operate
Therefore, the door lo c k will be on during the w ater va lve
operation.
4. The door needs to be secured for the Water Valve to operate.
Therefore, the door lock will be on during the water valve operation.
5. If there is an y problem with Water Valve, PCB A ssy. or Wire
Harness, thewater valves could not operate. So, t o make sure
for the water valves to operate, checkvisually if water comes
5. If there is any problem with Water Valve, PCB Assy. or Wire Harness, the
out with each Water Va lve On mode .
water valves could not operate. So, to make sure for the water valves to
operate, check visually if water comes out with each Water Valve On mode.
Motor Test:
1. To enter the Motor Test, press the Spin Key while model information is being
displayed during the Quick Test Mode.
2. Each time the Spin Key is pressed, it will cycle through the operations on the
left flow chart.
4. The Door Lock will be on during the motor operation.
5. If there is any problem with Motor, PCB Assy. or Wire Harness,related error
codes will be displayed.
Door Lock/Unlock Test:
1. To check the Door Lock/Unlock operation, press the Soil Level Key while
model information is being displayed during the Quick Test Mode.
2. Each time the Soil Level Key is pressed, it will cycle through the Door Lock/
Unlock operations on the left flow chart.
3. If the Soil Level Key is pressed during Door Lock and Water Valve, Motor or
Drain Pump operation, all of the operations will stop. And, when the Soil Level
Key is pressed again,the door will be released.
4. If there is any problem with Door Switch, PCB Assy. or Wire Harness, related
error codes will be displayed.
Drain Pump Test:
1. To check the Drain Pump operation, press the Signal Key while model
information is being displayed during the Quick Test Mode.
2. Each time the Signal Key is pressed, it will cycle through the operations on the
left flow chart.
3. The Drain Pump operation is independent.
Therefore, it will operate regardless of Door Lock/Unlock.
4. If there is any problem with Drain Pump, PCB Assy. or Wire Harness, the
Drain Pump will not operate.
So, its operation needs a visual inspection.
not have
.