Download Print this page
Progressive Dynamics PD4635 Installation And Operation Manual

Progressive Dynamics PD4635 Installation And Operation Manual

Replacement converter pd4600 series

Advertisement

Quick Links

I.
LIMITED WARRANTY: Progressive Dynamics, Inc. warrants its power control center to be free
from defects in material or workmanship under normal use and service; and limits the remedies to
repair or replacement.
II. DURATION: This warranty shall extend for a period of two years from the original date of purchase,
and is valid only within the continental limits of the United States and Canada.
III. WARRANTY EXCLUSIONS: This warranty specifically does not apply to:
A. Any product which has been repaired or altered in any way by an unauthorized person or service
station;
B. Damage caused by excessive input voltage, misuse, negligence or accident; or an external force;
C. Any product which has been connected, installed or adjusted or used other than in accordance with
the instructions furnished, or has had the serial number altered, defaced or removed;
D. Cost of all services performed in removing and re-installing the power converter; and
E. ANY LOST PROFITS, LOST SAVINGS, LOSS OF USE OF ENJOYMENT OR OTHER
INCIDENTAL DAMAGES ARISING OUT OF THE USE OF, OR INABILITY TO USE, THE
PRODUCT. THIS INCLUDES DAMAGES TO PROPERTY AND, TO THE EXTENT
PERMITTED BY LAW, DAMAGES FOR PERSONAL INJURY. THIS WARRANTY IS IN
LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.
V. CLAIM PROCEDURE: Upon discovery of any defect, Progressive Dynamics, Inc. shall be supplied
the following information at the address listed in this manual:
A. Name and address of the claimant;
B. Name, model and serial number of the product;
C. Application in which product was installed. (Includes manufacturer, model and model year where
applicable)
D. Date of purchase; and
E. Complete description of the claimed defect.
Upon determination that a warranty claim exists (a defect in material or workmanship occurring under
normal use and service,) the converter section shall be shipped postage prepaid to Progressive
Dynamics, Inc. together with proof of purchase. The product will be repaired or replaced and returned
postage prepaid.
Extended warranties are
available for purchase at
www.progressivedyn.com
Installation and Operation Guide for
PD4600 Series Replacement Converter

LIMITED WARRANTY

Progressive Dynamics Inc.
507 Industrial Rd.
Marshall, MI 49068
service@progressivedyn.com
www.progressivedyn.com
110197F

Advertisement

loading

Summary of Contents for Progressive Dynamics PD4635

  • Page 1: Limited Warranty

    IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase. V. CLAIM PROCEDURE: Upon discovery of any defect, Progressive Dynamics, Inc. shall be supplied the following information at the address listed in this manual: A.
  • Page 2: Installation Instructions

    WFCO model 8955 SAFETY FIRST!!! To insure immediate and continued safety of installation and use of your new Progressive Dynamics Power Converter, please adhere to the following guidelines for ALL installations: Do NOT install a converter whose amperage rating is higher than the one originally installed in your application.
  • Page 3 Replacement instructions for: Parallax/Magnetek Models: 6336, 6345, 6355, 7345, 7355 Removal: Disconnect all power sources to the unit. Remove front panel by removing (4) screws at bottom of panel. Remove AC power section cover by removing (2) screws. Disconnect the neutral (white) converter feed wire from distribution block, and hot (black) wire from AC branch breaker.
  • Page 4: Installation

    Replacement instructions for: Parallax/Magnetek Models: 7155 Removal: Disconnect all power sources to the unit. Remove front panel by removing (6) screws at bottom of panel. Remove AC power section cover by removing (2) screws. Disconnect the neutral (white) converter feed wire from distribution block and hot (black) wire from AC branch breaker. If the utility pigtail is used, remove wire nut.
  • Page 5 Replacement instructions for: WFCO Models: 8935, 8945, 8955 Removal: Disconnect all power sources to the unit. Remove front panel by opening access door and removing (2) screws. Disconnect the neutral (white) and ground (green) converter feed wires from distribution blocks and hot wire from AC branch breaker.
  • Page 6 The DC panel features 12 positions, rated for up to 20A, for accessories including ten low-to-full current rated branches. These can be used for lower current devices such as smoke and CO detectors. Each branch has a red LED light that indicates which fuse has blown. PD4635 (LI) PD4645 (LI)

This manual is also suitable for:

Pd4645Pd4655