Summary of Contents for Glendinning Cablemaster

  • Page 1 ABLEMASTE ABLEMASTE Shore Power Cable Storage System GUIDE TO: DESCRIPTION INSTALLATION CM-7 for 50 amp OPERATION CM-8 for 100 amp CM-4 for 30 amp Phone: (843) 399-6146 740 Century Circle Fax: (843) 399-5005 Conway, SC 29526 www.glendinningprods.com...
  • Page 2 American Boat and Yacht Council, Inc. This manual reflects practices and standards in effect at the time of publica- tion and is intended only as a guide to understand the Cablemaster. Glendinning Marine Products, Inc. will not be liable for any loss, dam- age, incidental or consequential damages of any kind, arising in con- Paul &...
  • Page 3 2) CM-7 Cablemaster — the CM-7 (the workhorse of the Cablemaster line) was designed to handle 50 amp shore power cable. 3) CM-8 Cablemaster — the CM-8 is our “heavy duty” version of the CM-7. The CM-8 will handle 100 amp shore power cable. You definitely don’t want to be extending and retracting this heavy cable by hand! All of these units can be configured to your boat’s specifications by utilizing the many accessories which aid in instal-...
  • Page 4 Perhaps the prime consideration in determining the best location for mounting your Glendinning Cablemaster is to remember that the key to a good installation is allowing enough room for the shore power cable to coil without restriction. The power unit should be mounted directly over the storage container, but may be offset a maximum of 20 degrees where space deems it to be necessary.
  • Page 5: Types Of Installations

    NSTALLATIONS STANDARD (CLOSE COUPLED) INSTALLATION The Cablemaster works best when the power unit is mounted directly above the stor- age container. This will ensure proper cable extension and retraction and is recommended providing storage space is available where hawse pipe is to be mounted (Fig. 2).
  • Page 6: Installation

    Unless the shore power cable is being directed vertically through a PVC pipe, you are now ready to wire the Cablemaster to the boat’s DC electrical system. If the shore power cable is being direct- ed vertically through PVC pipe (see drawing below) it is necessary to relocate the guide roller assembly with the out-limit switch from the bottom of the power unit to the lower end of the PVC pipe.
  • Page 7: Wiring Instructions

    IRST is any uncertainty as to the proper methods of wiring, a qualified and competent electrician should do the wiring. , overcurrent protection (fuse or circuit breaker) must be provided in the power supply to the Cablemaster. On ECOND 12v DC systems, a 20 amp fuse or circuit breaker should be used; on 24v DC systems, a 15 amp fuse or circuit breaker is required.
  • Page 8 SWITCH BLACK relay assembly for 12 or 24 volt DC depending on your boat’s voltage. The voltage for each Cablemaster is located on the unit’s label. The Cablemaster should be connected to a separate circuit CABLEMASTER RELAY ASSEMBLY # 04034 (12, 24 volt DC)
  • Page 9: Cable Installation

    Cablemaster. The power cable should be firmly strapped down, using metal or heavy duty plastic wiring straps, to the bottom of the cable storage area so that in no way will the Cablemaster pull on the power cable’s electrical connection.
  • Page 10: Maintenance

    DO NOT USE any cleaner that will leave a waxy film on the shore power cable. The waxy film will cause slippage between the Cablemaster’s main pulley and your shore power cable. It is recommended to use a mild soap and water to clean your...
  • Page 11: Shooting Guide

    1) Disconnect the power cord plug from the dock power cord plug. source. 2) Walk to dock power source and plug power cord into 2) While holding power plug, walk to Cablemaster. recepticle. 3) Flip the power switch to the position.
  • Page 12 ABLEMASTER IMENSIONS...
  • Page 13 CM-4 DIMENSIONS Specifications: Voltage: 12v DC or 24v DC 4-5 amps under load Amperage: 5-1/2” L x 6” W x 10” H Dimensions: (power unit only) 9 lbs. Weight: 30amp 110 volt cable 3/4” diameter Capacity: Length of cable: determined by available storage space 17-7/8"...
  • Page 16: Wiring Diagram

    IRING IAGRAM CM-7 & CM-8 WHITE IRING IAGRAM POWER ELAY SSEMBLY BLACK SWITCH CABLEMASTER RELAY ASSEMBLY # 04034 (12, 24 volt DC) BATERY 12 / 24v Power POSITIVE (+) DC Input Switch Pos. + Red 1 (Remote - RED) WHITE BATTERY Neg.
  • Page 17 5. GLENDINNING MARINE PRODUCTS, INC. does not assume the costs of removal and/or installation of the product or any other incidental costs which may arise as a result of any defect in materials or workmanship.
  • Page 18 50 amp Shore Power Cable plug cover — White — this option allows the remote ADIO EMOTE ONTROL PTION operation of the Cablemaster unit. 04146 Radio Remote Control Kit - includes 2 transmitters! 04147 Spare / replacement transmitter 04153 RF Noise Filter - improves operational range of transmitter...
  • Page 19: Product Registration

    DDRESS _______________________________________________________________________ TATE _______________________________________________________________________ OUNTRY HONE MAIL _________________________________________ WOULD YOU LIKE TO RECEIVE INFO ON & Y ODEL EAR OF ANUFACTURE NEW PRODUCTS FROM GLENDINNING _________________________________________ ABLEMASTER ERIAL UMER _______________________________________________________ THANK YOU! HAT WOULD YOU LIKE TO SEE IMPROVED CHANGED...
  • Page 20 Hawse Pipe Template Diameter 3-5/8" cut on outside of line Diameter 17/64" 4 Plcs. PLACE STAMP HERE PRODUCT WARRANTY INFORMATION 740 C ENTURY IRCLE , SC 29526-8274 ONWAY SML-CMMAN PRINT DATE: 06/08...

Table of Contents