USER MANUAL PIL – 19/99DLT REMOTE CONTROL
A remote control with a graphical display and an option to add names to channels and time programs with sun function.
The remote control is available in two versions with a different number of channels:
PIL-19DLT – 19-channel remote control,
PIL-99DLT – 99-channel remote control
and in three colour versions (white, black-white, black).
The remote control has seven buttons:
At the front panel:
▲ "UP" button
"STOP" button
▼ "DOWN" button
+ "PLUS" button
- "MINUS" button
1. Remote control menu:
Press M under the battery cover to enter the remote control menu.
Press ▲ "UP" and ▼ "DOWN" to move through the menu. Press "STOP" to select one of the options. Press "STOP"
to return to the main menu.
Available menu options:
- Programs
- Names
- Clock
- Partial
- Sun
- Other
Press M again to exit.
Programs:
Set and modify programs for automatic open, close, partial and stop (e.g. lighting control) for an individual roller shutter or a group
of roller shutters at a specific time and day of the week. 32 programs (00 to 31) can be set. The programs can be enabled (Active) or
disabled (Inactive). Days of the week for the program can be set as a range - from day to day inclusive.
"Mon-Mon" is Monday only, "Sat. - Sun" is Saturday and Sunday and "Mon-Sun" includes all days of the week. The time can be set
in hours and minutes or as a sunrise (sun) and sunset (moon) time. Minutes can be set as a multiple of 5 only. A channel number
between 00 to 19 (PIL-19DLT) or 0 to 99 (PIL-99DLT) and an action required: open ("Up"), close ("Dn"), partial ("Part") or stop
("Stop") must be defined to create a program. Press "▲" and "▼" to change the value indicated with a cursor (underlined).
Press "-" or "+" to move the cursor. Press "STOP" to move the cursor to the program number. Change the number to save any changes to the existing
program.
The number of the last program is displayed after the programmed action is completed.
CAUTION!
The times set must not be identical (open/close time for two or more roller shutters must not be identical).
To set the same time for several roller shutter, create a group of roller shutters (assign the same remote channel number for
several roller shutters).
CAUTION!
The time programs are executed if the clock icon is shown in the top right corner. Press the clock button (under the battery cover) to disable the
time programs.
Names:
Each channel can be assigned a name including up to 16 characters (capital letters or digits) in two lines, 8 characters each.
Press "▲" or "▼" to change the selected (underlined) value. Press "-" or "+" to move the cursor. Press "STOP or change the channel
number to save the name.
Clock:
The clock options include setting summer/winter time, day of the week, date (day, month, year) and time (hours and minutes).
Press "▲" or "▼" to change (set) the underlined value. Press "-" or "+" to move the cursor. You can set the day of the week, month,
year, hours and minutes. Press "STOP"
Daylight saving time is not set automatically (must be set manually).
Partial:
The partial function allows to open the slats of the roller shutter slightly. The gap size corresponds to the size (Val.) parameter.
This function can be used in time programs.
Num.: 00
roller shutter number 00 to 19 (PIL-19DLT) or 00 to 99 (PIL-99DLT)
Val .: 00
00 to 15
Sun
Set the roller shutter operation based on actual sunrise and sunset times. Set the sunrise/sunset time (hours and minutes) for 22
December in your location. Press "CLOCK"
significantly deviate from the actual sunrise/sunset time for your location. Otherwise, the time will not be displayed.
Correction (Korekta): set the roller shutter closing delay (minutes).
Other:
Bright.
display brightness 00 to 16
Lang.
menu language English (EN), French (FR), German (DE), Polish (PL)
Program version
software version
Under the battery cover:
"CLOCK" button
M "MENU" button
time program settings
adding names to channel numbers
time and date settings
roller shutter ventilation settings (available in time programs)
sun function settings
menu language and display brightness settings
to confirm.
to display the sunrise/sunset time for the current day. The time set should not
Mo
11:48
again
OPCJE
Programs
Names
Clock
Partial
Sun
Other
Program
00
Active
Mon.- Sun.
07 : 55
Nr 06
Dn
Program
00
Active
Sun.-Sun.
Nr 06
Up
NAME EDIT
12
SALON
RIGHT
CLOCK
Time:
Winter
Hour:
13:33
DATE
Fri
21.09.2017
PARTIAL
Num.:
05
Val.:
02
SUN
22 XII
Sunrise
08:00
Sunset
19:00
Offset
60
OTHERS
Bright
15
Lang.
PL
Program version
dlt99.06

Advertisement

loading

Summary of Contents for Inel PIL–19DLT

  • Page 1 11:48 USER MANUAL PIL – 19/99DLT REMOTE CONTROL A remote control with a graphical display and an option to add names to channels and time programs with sun function. The remote control is available in two versions with a different number of channels: ...
  • Page 2 2. Registering the remote controls PIL-19/99DLT remote control can be used to control any channel, provided that the channel has been previously registered for a specific motor or controller. Entering the programming mode: 14:24  Initial programming of radio controlled drives and ST-01RL controllers: connect 230 VAC power supply to the drive/controller, press ▲...

This manual is also suitable for:

Pil–99dlt