Configuration Guide; Table 5: Advanced Display Configuration - Honeywell SMV800 Quick Start Installation Manual

Smartline multivariable transmitter
Hide thumbs Also See for SMV800:
Table of Contents

Advertisement

Configuration Guide

Table 5
shows the transmitter display configuration.
Key
Parameters in Italics are read-only.
* HART only
** HART and DE
*** HART and Modbus
Pressure Parameters
Temperature Parameters

Table 5: Advanced Display Configuration

Critical
Diagnostics
Non-Critical
Diagnostics
Display
Setup
(continued)
Screen 1 ..
...to
Screen 8
Set Time Stamp***
DP Zero Correct
DP LRV Correct
DP URV Correct
DP Reset Correct
SP Zero Correct
SP LRV Correct
Calibration
SP URV Correct
SP Reset Correct
Temp Cal Points **
Temp Cal Lo Corr
Temp Cal Hi Corr
Temp Reset Corr
DAC Trim **
Loop Test **
Common Parameters
Flow Parameters
Totalizer Parameters
Active Diags
Meter Body
Meter Body Comm
Temp Sensor Board
Temp Input
Temp Sensor Comm
Comm Module
Comm VCC Fault
Active Diags
Analog Out Mode **
Write Protected (Only Modbus)
DP Zero Correct
DP Span Correct
Meter Body Input
Meter Body Temp
Meter Body Comm
Pressure Fac Cal ***
Temp Cal Correct
Temp Module Temp
Temp Input Range
CJ Range
Temp Input
Temp Input TB6
Temp Fac Cal
Temp Comm
Screen Format
PV Selection
PV Scaling ***
Display Units
Custom Units ***
Decimals
Scaling Low Lim ***
Scaling High Lim ***
Scaling Unit ***
Trend Hours
Disp Low Lim
Disp High Lim
Scrn Custom Tag
Hour, Minute, Year, Month, Day
Set Time Stamp
Do DP Zero Correct
Set Time Stamp*
Do DP LRV Correct
Set Time Stamp
Do DP URV Correct
Set Time Stamp
Do DP Reset Correct
Set Time Stamp
Do SP Zero Correct
Set Time Stamp
Do SP LRV Correct
Set Time Stamp
Do SP URV Correct
Set Time Stamp
Do SP Reset Correct
Temp Cal Lo Pt **
Temp Cal Hi Pt **
Set Time Stamp
Do Temp Cal Lo
Set Time Stamp
Do Temp Cal Hi
Set Time Stampv
Reset Temp Corr
Trim Zero **
Trim Span **
Set DAC Normal **
Set DAC Output **
Set DAC Normal **
Diagnostics
(continued)
Non-Critical
LCD Contrast
Display Setup
Common Setup
Device Setup
HART Setup*
Device
Modbus Setup*
Setup
(Modbus only)
HART Date*
Modbus Date
(Modbus only)
Dev Instl Date
Pres Sens Instl
(Modbus only)
Pressure Params
DP LRV
DP URV
Set DP LRV **
Pressure
Set DP URV **
Setup
DP Factory Cal ***
SP LRV
SP URV
Set SP LRV **
Set SP URV **
SP Factory Cal ***
MBT LRV (Mbus only)
MBT URV (Mbus only)
PV Out of Range **
Comm Module Temp **
Supply Voltage
DAC Temp Comp **
Display Setup
Flow Divide by 0
Flow Sqrt of Neg
Flow Direction
Flow SP/PT Comp
Totalizer Max ***
Totalizer Status ***
Flow Output ***
DP Sim ON/OFF
SP Sim ON/OFF
PT Sim ON/OFF
Flow Sim ON/Off
DP Out of Range (Modbus only)
SP Out of Range (Modbus only)
PT Out of Range (Modbus only)
Flow Out of Range (Modbus only)
MBT Out of range (Modbus only)
Set Contrast
Set Password
Language
Screen Rotate
Rotation Time
DP Units
SP Units
Temp Units
Mass Fl Units
Vol Fl Units
Totalizer Unit ***
MBT Unit (Modbus only)
Tag ID
Loop Source **
NAMUR Output **
Device ID
Universal Rev
Field Device Rev
Final Assy Num
Loop mA
Poll Address
Slave ID
Baud Rate
Final Assy Num
Turn Around Delay
Parity
Year, Month, Day, Write Date
Year, Month, Day, Write Date
Year, Month, Day, Instal Date, Write
Date
Device DP Unit
Device SP Unit
MBT Unit
DP Damping sec
SP Damping sec
Transfer Function **
Filter Perform ***
DP LRV (in preferred unit)
DP URV(in preferred unit)
Set DP LRV(in preferred unit)
Set DP URV(in preferred unit)
Active Cal Set ***
Select Cal Set ***
SP LRV (in preferred unit)
SP URV (in preferred unit)
Set SP LRV (in preferred unit)
Set SP URV (in preferred unit)
Active Cal Set ***
Select Cal Set ***
MBT LRV (in preferred unit)
MBT URV (in preferred unit)

Advertisement

Table of Contents
loading

Table of Contents