PAJ WIO 200B User Manual page 51

Water in oil sensor
Table of Contents

Advertisement

Dead
Display indicate nothing
display
Relay
Relay-state while alarm is on
Sensor
How to check the mA output from
sensor?
Tel: +45 74 43 71 81 • Fax: +45 74 43 71 91 • CVR: 3459-1229 • www.paj.dk • e-mail: paj@paj.dk
APPROVALS: ISO 9001, ISO 14001, ISO 13485, IEC 61340-51 & IPC-A-610 CLASS 3
PAJ Sensor A/S • Grundtvigs Allé 163 • DK-6400 Sønderborg
03-01-0501-CRJ-04 Side 51 af 53
Maybe is 24V dc supply interrupted
to the display. There shall be 24V
dc at this connector.
Remove jumper in pin 11 and pin
12. In order to ensure that there
can be measured mA must pin 11
and pin 12 must be screwed.
Remember to set the measuring
instrument in dc mA and connect
test leads correctly in the
measuring instrument. Sensor is
alright when measuring a value
between 4 and 20 mA. Is the result
about 2 mA then there is an
internal sensor error, so the sensor
must be sent for repair. Is the
result 0 mA, tjek if the sensor get
24 Vdc power.