PAJ WIO 200B User Manual page 37

Water in oil sensor
Table of Contents

Advertisement

Abstract representation of the H-Alarm and HH-Alarm button and LED
function:
HHA-LED
HA-LED
a
HH-Alarm Relay
0,9
H-Alarm Relay
0,5
IMPORTANT
The display is an indication of the water level in the oil. Display can be
shipped as PPM or a
Upon ordering a PPM display the customer must specify the water
saturation point in PPM of the used oil at the preferred working
temperature of the oil. The saturation point is typically between 3000-
10000 PPM. Alternatively the customer can ship 10 liters of oil to PAJ
Sensor A/S for inspection including specification of the working oil
temperature.
WARNING
All displays will show from positive values when operating properly. There
will appear a negative value during start-up, after 5 seconds the value will
be in positive measurement range. Otherwise, if a negative value is
present the Terminal box might have been installed incorrectly.
Tel: +45 74 43 71 81 • Fax: +45 74 43 71 91 • CVR: 3459-1229 • www.paj.dk • e-mail: paj@paj.dk
APPROVALS: ISO 9001, ISO 14001, ISO 13485, IEC 61340-51 & IPC-A-610 CLASS 3
HA-Button pressed
off
flashing
ON
off
w
Figure 2: H-Alarm and HH-Alarm button function
.
w
PAJ Sensor A/S • Grundtvigs Allé 163 • DK-6400 Sønderborg
03-01-0501-CRJ-04 Side 37 af 53
HHA-Button pressed
flashing
flashing
OFF
ON
flashing
t