DINA DN3PD1 Original Instruction Manual

DINA DN3PD1 Original Instruction Manual

Safety switchgear
Hide thumbs Also See for DN3PD1:

Advertisement

DN3PD1
Original Instruction Manual
valid for ID-No: 33PD02
Safety switchgear
to monitor the speed of three-phase and
single-phase motors without sensor
we are safety.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DN3PD1 and is the answer not in the manual?

Questions and answers

Summary of Contents for DINA DN3PD1

  • Page 1 DN3PD1 Original Instruction Manual valid for ID-No: 33PD02 Safety switchgear to monitor the speed of three-phase and single-phase motors without sensor we are safety.
  • Page 3 EU-Konformitätserklärung EC-Declaration of Conformity DINA Elektronik GmbH Esslinger Str. 84 72649 Wolfschlugen Germany Phone +49 7022 95170 +49 7022 9517700 info@dina.de www.dina.de Wir erklären, dass folgendes Produkt die einschlägigen Harmonisierungsrechtsvorschriften der Union erfüllt. We declare that the following product is in conformity with the relevant Union harmonization legislation.
  • Page 4: Table Of Contents

    DN3PD1 Inhaltsverzeichnis Content Intended Use Approvals Safety parameters Ordering data Safety regulations Important information and validation Function description Switching threshold Start-up monitoring Minimum switch-off time Acknowledge function Functional diagram Schematic, operating element and display Terminal description Applications Motor with frequency converter...
  • Page 5 DN3PD1 Always read the additional applicable online documentation before working on/with the safety switchgear. Make sure you always work with the valid documentation. This is available online at http://www.dina.de/downloads/ Dispose of the device according to the national environmental regulations. Symbol and Notes: WARNING Observe the safety regulations and installation notes in the corresponding section.
  • Page 6: Intended Use

    DN3PD1 Intended Use Intended Use Safety switchgear to monitor the speed of three-phase and single-phase motors without sensor. • Two speed thresholds are possible: minimum speed and maximum speed. • The unit meets Cat. 4/ PL e acc. to ISO 13849-1, SIL (CL) 3 acc. to IEC 62061 and IEC 61508.
  • Page 7: Safety Regulations

    Properly dispose of the device at the end of its service life. • If these regulations are not adhered to or in the event of improper use, DINA Elektronik GmbH accepts • absolutely no liability for the resulting property damages or personal injury.
  • Page 8: Function Description

    DN3PD1 Function description Function description The two-channel evaluation unit of the safety switchgear module measures the frequency of the effective rotat- ing field of the motor at the measuring terminals L1, L2, L3. If the parameterized switching threshold frequencies are exceeded or undershot (V-LIMIT 1 and V-LIMIT 2), or an internal or external fault exists, the enabling current paths 13/14, 23/24 open immediately.
  • Page 9: Functional Diagram

    DN3PD1 Function description Signal that is longer than10s does not cause a reset. • For parameterization of the acknowledgment function see chapter " Configuration of the switching • threshold and acknowledgement". Functional diagram Automatic acknowledgement V-LIMIT 1 and V-LIMIT 2 Manual acknowledgment V-LIMIT 1 and V-LIMIT 2 (V-LIMIT 1 must be at least 1.1Hz!)
  • Page 10: Schematic, Operating Element And Display

    DN3PD1 Function description Schematic, operating element and display L1, L2, L3 Measuring inputs Power supply +24V DC Acknowledgment in- SPEED O1, O2 Diagnostics outputs 13-14/23-24 Enabling contacts Configuration button b1, b2, b4, b8 parameter 1-15 Ready for operation 24 V DC...
  • Page 11: Applications

    24V DC Operation on motors with star-delta connection or pole changeover is possible. For pole-changing motors, please note that DN3PD1 detects the frequency and not the speed! DN3PD1 The measuring inputs L1 and L3 are bridged and directly con- nected to W1 on the motor.
  • Page 12: Wiring

    DN3PD1 Mounting and removal Wiring Conductor cross-section of 1.5 mm² must not be undercut. • Use Copper wires approved up to 60°C/75°C. • For of wire end sleeve is recommended. • Loads connected to the measuring wires are not allowed.
  • Page 13: Parameterization Of The Switching Thresholds

    DN3PD1 Parameterization of the switching thresholds Parameterization of the switching thresholds Important notes for parameterization Use a VDE-insulated screwdriver according to EN 60900 to press the SET button. • The switching threshold and acknowledgement must be set correctly in order to ensure safe operation;...
  • Page 14: Configuration Of The Switching Threshold And Acknowledgement

    DN3PD1 Parameterization of the switching thresholds Configuration of the switching threshold and acknowledgement The current settings can be checked by briefly pressing the SET button. The LEDs show the parameters binary coded in five steps (Level). Two levels each determine V-LIMIT 1 and V-LIMIT 2 (see frequency table), the fifth level indicates the type of acknowledgment.
  • Page 15: Example For Configuration

    DN3PD1 Parameterization of the switching thresholds Example for configuration Acknowledgement V-LIMIT 1 = 1,0 Hz V-LIMIT 2 = 297,9 Hz Level 1.1 Level 1.2 Level 2.1 Level 2.2 manual column 1 row 10 column 14 row 6 18-09-27 / 33pd02-V0743...
  • Page 16: Diagnostics

    DN3PD1 Diagnostics Diagnostics The 2-color LEDs (b1, b2, b4, b8) indicate operational readiness, switching status, internal and external errors. The semiconductor output O1 is switched on when the frequency is within the parameterized range. See Fig. 8-1 The semiconductor output O2 indicates the operational readiness. This switches off in case of an error.
  • Page 17: Technical Data

    DN3PD1 Technical data Technical data Ambient conditions Ambient temperature (operation) -20 to +55°C DIN IEC 60068-2-3 Ambient temperature (storage) -40 to +85°C DIN IEC 60068-2-3 Maximum altitude max. 2000m (above sea level) Vibration resistance 3 axis Sinus 10–55Hz, 0,35mm, 10 cycles, 1 octave/min...
  • Page 18: Relay Load Curve

    DN3PD1 Dimensions Relay load curve 1000 ohmic load L/R = 0ms inductive load L/R = 40ms L / R = 0 ms L / R = 40 ms DC Schaltstrom (A) / DC Switching current (A) WARNING Loads with high capacitive component can destroy the output contacts because the switching cur- rent is very high.
  • Page 20 DINA Elektronik GmbH Esslinger Str. 84 D72649 Wolfschlugen Phone +49 7022 95170 +49 7022 9517700 info@dina.de www.dina.de...

Table of Contents