This manual is an unpublished work and contains the trade secrets and confidential information of Neptune Technology Group Inc., which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part, in any form or by any means, electronic or mechanical for any purpose, without the express written permission of Neptune Technology Group Inc.
This section provides a general description of the Neptune Technology Group cellular meter interface unit (subsequently referred to as CMIU). The CMIU by Neptune is a compact electronic device that collects meter reading data from an encoder register. It then transmits the data for collection. The collected data is stored and downloaded into the utility billing system for processing.
2 Specifications This section provides you with the specifications for the CMIU. Electrical Specifications The power is supplied by a Lithium battery. Encoder Register Interface Supported Encoder Maximum Cable Length 300 feet (91 meters) Neptune ARB ® ™ ® 500 feet (152 meters)
3 General Installation Guidelines This section describes tools, materials, and general installation information for the CMIU. Tools and Materials Tables 1 and 2 show the recommended tools and materials you need to successfully install the CMIU. It is possible that some items do not apply to your specific installation, or the list does not contain all required tools or materials.
Verify that the ID number(s) matches the ID number(s) on the MIU you are about to install, if the site worker already has an MIU ID number. Verifying/Preparing the Encoder Register The CMIU is designed for use with the following encoder registers: • ARB V •...
Strip off ¾ inch of jacket from the cable, leaving only the three insulated wires. Take precautions not to nick or cut the insulation on the three wires, strip off ½ inch of insulation from each of the three wires. Figure 2 Wiring a Neptune Encoder Register CMIU Installation and Maintenance Guide...
Figure 4 Cable Threaded Around Strain Relief Posts Apply sealant liberally and ensure that it encapsulates the terminal screws and exposed wires. See Figure 5. Neptune requires Novaguard G661 sealant or Dow Corning compound 4. CMIU Installation and Maintenance Guide...
• Do not exceed maximum cable lengths as defined in “Specifications - CMIU” on page 2. • If the encoder register is prewired and potted, use Scotchloks for con- necting the register to the MIU. CMIU Installation and Maintenance Guide...
4 Wall Installation This chapter provides instructions for installing the CMIU. Installing the Cellular MIU Removing the Main Housing Complete the following steps to install the wall MIU. Remove the main housing from the mounting adapter. The Hi-Lo fastener for securing the main MIU housing to the adapter plate is shipped separately.
For rear cable entry, store excess wire and Scotchloks in the hollow cavity in the back of the MIU using the strain relief guides as shown inFigure 11. Cable exit notch Figure 11 Cable in Back of Mounting Adapter CMIU Installation and Maintenance Guide...
Position the magnet against the left side of the MIU directly in line End swipe here with the Neptune logo, and swipe it bringing it from the side and around the corner to the top to activate the MIU. SeeFigure 14.