Summary of Contents for Neptune CMIU

  • Page 1 Certification Exhibit FCC ID: P2SCMIU-VZW-1 FCC Rule Part: 15.247 ACS Project Number: 15-3049 Manufacturer: Neptune Technology Group Model: CMIU Manual 2320 Presidential Drive, Suite 101, Durham, NC 27703 USA Voice: 919-381-4235 Fax: 770-831-8598...
  • Page 2 Celluar MIU Installation and Maintenance Guide...
  • Page 4 Cellular MIU Installation and Maintenance Guide...
  • Page 5 This manual is an unpublished work and contains the trade secrets and confidential information of Neptune Technology Group Inc., which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part, in any form or by any means, electronic or mechanical for any purpose, without the express written permission of Neptune Technology Group Inc.
  • Page 6: Table Of Contents

    Specifications - CMIU MIU ........
  • Page 7 Contents Notes: CMIU Installation and Maintenance Guide...
  • Page 8 Wiring a Neptune Encoder Register ........
  • Page 9 Figures Notes: CMIU Installation and Maintenance Guide...
  • Page 10 Recommended Materials........... . . 4 CMIU Installation and Maintenance Guide...
  • Page 11 Tables Notes: viii CMIU Installation and Maintenance Guide...
  • Page 12: Cellular Miu

    This section provides a general description of the Neptune Technology Group cellular meter interface unit (subsequently referred to as CMIU). The CMIU by Neptune is a compact electronic device that collects meter reading data from an encoder register. It then transmits the data for collection. The collected data is stored and downloaded into the utility billing system for processing.
  • Page 13: Specifications

    2 Specifications This section provides you with the specifications for the CMIU. Electrical Specifications The power is supplied by a Lithium battery. Encoder Register Interface Supported Encoder Maximum Cable Length 300 feet (91 meters) Neptune ARB ® ™ ® 500 feet (152 meters)
  • Page 14: General Installation Guidelines

    3 General Installation Guidelines This section describes tools, materials, and general installation information for the CMIU. Tools and Materials Tables 1 and 2 show the recommended tools and materials you need to successfully install the CMIU. It is possible that some items do not apply to your specific installation, or the list does not contain all required tools or materials.
  • Page 15: Safety And Preliminary Checks

    Verify that the ID number(s) matches the ID number(s) on the MIU you are about to install, if the site worker already has an MIU ID number. Verifying/Preparing the Encoder Register The CMIU is designed for use with the following encoder registers: • ARB V •...
  • Page 16: Installation Of A Register (Non Pre-Wired Or Potted Only)

    Strip off ¾ inch of jacket from the cable, leaving only the three insulated wires. Take precautions not to nick or cut the insulation on the three wires, strip off ½ inch of insulation from each of the three wires. Figure 2 Wiring a Neptune Encoder Register CMIU Installation and Maintenance Guide...
  • Page 17: Miu Color Code For Wires

    Figure 4 Cable Threaded Around Strain Relief Posts Apply sealant liberally and ensure that it encapsulates the terminal screws and exposed wires. See Figure 5. Neptune requires Novaguard G661 sealant or Dow Corning compound 4. CMIU Installation and Maintenance Guide...
  • Page 18: Application Of The Sealant

    • Do not exceed maximum cable lengths as defined in “Specifications - CMIU” on page 2. • If the encoder register is prewired and potted, use Scotchloks for con- necting the register to the MIU. CMIU Installation and Maintenance Guide...
  • Page 19: Wall Installation

    4 Wall Installation This chapter provides instructions for installing the CMIU. Installing the Cellular MIU Removing the Main Housing Complete the following steps to install the wall MIU. Remove the main housing from the mounting adapter. The Hi-Lo fastener for securing the main MIU housing to the adapter plate is shipped separately.
  • Page 20: Applying The Scotchloks

    For rear cable entry, store excess wire and Scotchloks in the hollow cavity in the back of the MIU using the strain relief guides as shown inFigure 11. Cable exit notch Figure 11 Cable in Back of Mounting Adapter CMIU Installation and Maintenance Guide...
  • Page 21: Activating And Completing The Installation

    Position the magnet against the left side of the MIU directly in line End swipe here with the Neptune logo, and swipe it bringing it from the side and around the corner to the top to activate the MIU. SeeFigure 14.
  • Page 22: By Phone

    A description of any actions taken to correct the issue. By Fax To contact Neptune Customer Support by fax, send a description of your problem to (334) 283-7497. Please include on the fax cover sheet the best time of day for a Support...
  • Page 23 Contact Information Notes: CMIU Installation and Maintenance Guide...
  • Page 25 Fax: (905) 858-0428 Tel: (525) 55203 5294 / (525) 55203 5708 TAKE CONTROL Fax: (525) 55203 6503 neptunetg.com IM CMIU 11.15 Part No. XXXXX-XXX © Copyright 2015, Neptune Technology Group Inc. Neptune is a registered trademark of Neptune Technology Group Inc.