INSTALLATION INSTRUCTIONS

MODEL RXGY-G01 (SP20286)
FOR USE WITH (-)GRA, (-)GRJ, (-)GTA, (-)GTJ, (-)GFD, (-)GGD, (-)GRK,
(-)GTK, (-)GRS, (-)GTS, (-)GFE, (-)GGE, (-)GFG, (-)GJF, (-)GRL,
(-)GRM, (-)GTM, (-)GTC, (-)GRC & (-)GRB FURNACES
FOR USE WITH CONDENSING TANKLESS WATER HEATERS PER
KIT CONTENTS:
• Vent Cap
• Vent Plate
• Mounting Hardware
NOTE: Field-supplied pipe and fittings are
required to complete the installation.
THIS VENT KIT MUST BE INSTALLED BY A QUALIFIED SERVICE TECHNICIAN. CODES AND LOCAL UTILITY
REQUIREMENTS GOVERNING THE INSTALLATION OF GAS FIRED EQUIPMENT, WIRING, PLUMBING, AND FLUE
CONNECTIONS MUST BE ADHERED TO. IN THE ABSENCE OF LOCAL CODES, THE INSTALLATION MUST CONFORM
WITH THE NATIONAL FUEL GAS CODE ANSI Z223.1 "LATEST EDITION," OR CAN/CGA B149 INSTALLATION CODES.
THE LATEST CODE MAY BE OBTAINED FROM THE INTERNATIONAL APPROVAL SERVICES, 8501 E. PLEASANT
VALLEY RD., CLEVELAND, OHIO 44131, OR 55 SCARSDALE RD., TORONTO, ONTARIO, CANADA, M3B 2R3.
DO NOT OPERATE THE FURNACE OR TANKLESS WATER HEATER WITHOUT THE SIDE WALL CAP IN PLACE AS
RECIRCULATION OF COMBUSTION PRODUCTS MAY OCCUR. WATER MAY ALSO COLLECT INSIDE THE COMBUS-
TION AIR PIPE AND FLOW TO THE BURNER ENCLOSURE. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN
PRODUCT DAMAGE OR IMPROPER OPERATION, PERSONAL INJURY OR DEATH.
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED SERVICE PERSONNEL FOR PROPER INSTALLA-
TION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE
ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE, POSSIBLY RESULTING IN FIRE, CARBON
MONOXIDE POISONING, EXPLOSION, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP
DIRECT VENT – SIDE WALL VENT KIT
MANUFACTURE INSTRUCTION
IN A SAFE PLACE FOR FUTURE REFERENCE BY A SERVICEMAN.
This manual covers the installation of the RXGY-G01
Direct Vent Furnace – Side Wall Vent Kit. The
RXGY-G01 Vent Kit can be used for all above listed
furnace models or gas fired Direct Vent Condensing
Tankless Water Heaters, excluding models featuring
alternate terminations. See vent application charts in
applicable furnace installation instructions.
W RNING
W RNING
W RNING
IMPORTANT:
SUPERSEDES 92-102005-01-00
92-102005-01-01

Advertisement

loading

Summary of Contents for Rheem RXGY-G01

  • Page 1: Installation Instructions

    • Vent Cap Direct Vent Furnace – Side Wall Vent Kit. The • Vent Plate RXGY-G01 Vent Kit can be used for all above listed • Mounting Hardware furnace models or gas fired Direct Vent Condensing Tankless Water Heaters, excluding models featuring NOTE: Field-supplied pipe and fittings are alternate terminations.
  • Page 2 INSTALLATION - Side Wall Vent Kit IMPORTANT: Refer to Furnace or Condensing Tankless Water Heater Installation Instructions for complete information on installation of Side Vent Kit. (See Figures 1-3.) All applicable codes should be followed when determining vent location. FIGURE 1 VENT KIT INSTALLATION OPTIONS OPTION A OPTION B...