  • Page 1 Owner’s Guide Installation Instructions Electric Domestic Water Heater This water heater must be installed and serviced by an authorised person. Please leave this guide with the householder.
  • Page 2 Compliance Certificate. PATENTS This water heater may be protected by one or more patents or registered designs in the name of Rheem Australia Pty Ltd. TRADEMARKS ® Registered trademark of Rheem Australia Pty Ltd.
  • Page 3: Table Of Contents

    CONTENTS HOUSEHOLDER - We recommend you read pages 4 to 17. The other pages are intended for the installer but may be of interest About Your Water Heater ............4 Regular Care ................9 Water Supplies ................11 Save A Service Call ..............15 Installation ..................
  • Page 4: About Your Water Heater

    ABOUT YOUR WATER HEATER MODEL TYPE ® ® The Rheem water heater you have chosen will be either a Rheemglas Optima™ or RheemPlus™ model. The Optima model has a temperature adjusting knob on the lower front of the water heater. Rheemglas and Optima...
  • Page 5 ABOUT YOUR WATER HEATER HOTTER WATER INCREASES THE RISK OF SCALD INJURY This water heater can deliver water at temperatures which can cause scalding. Check the water temperature before use, such as when entering a shower or filling a bath or basin, to ensure it is suitable for the application and will not cause scald injury.
  • Page 6 The power supply cord and plug must be replaced with a genuine replacement part available from Rheem. Phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection.
  • Page 7 ABOUT YOUR WATER HEATER SINGLE ELEMENT MODEL This type of water heater has one heating unit with its own thermostat. The heating unit is at the base of the water heater. Continuous electricity supply This type of connection is suited to where the storage capacity is less than the normal daily usage.
  • Page 8 ABOUT YOUR WATER HEATER TO TURN OFF THE WATER HEATER If you plan to be away from home for only a few nights, we suggest you leave the water heater switched on. If it is necessary to turn off the water heater: Switch off the electrical supply at the isolating switch to the water heater.
  • Page 9: Regular Care

    – line the water heater should be checked by lower gently Rheem Service their nearest Accredited Service Agent. The temperature pressure relief valve should be checked for performance or replaced at intervals not exceeding 5 years, or more frequently in areas where “Water Supplies”...
  • Page 10 If the water is being delivered at a temperature exceeding 50°C, phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection. The valve should be replaced at intervals not exceeding 5 years, or more frequently in areas where there is a high incidence of water deposits (refer to “Water Supplies”...
  • Page 11: Water Supplies

    WATER SUPPLIES This water heater must be installed in accordance with this advice to be covered by the warranty. This water heater is manufactured to suit the water conditions of most public reticulated water supplies. However, there are some known water chemistries which can have detrimental effects on the water heater and its operation and / or life expectancy.
  • Page 12 WATER SUPPLIES TOTAL DISSOLVED SOLIDS & CONDUCTIVITY (vitreous enamel lined water heater cylinder) no warranty applies warranty applies to a vitreous enamel lined water heater cylinder if the to a vitreous correct coloured anode is used for the TDS / conductivity level of water enamel lined water heater TOTAL DISSOLVED SOLIDS (TDS) - mg/L...
  • Page 13 13. Refer to the cold water connection detail on page 27 for the position of the expansion control valve. Contact Rheem Service or their nearest Accredited Service Agent if a replacement heating unit is required. SATURATION INDEX (SI) ELECTRIC WATER HEATERS...
  • Page 14 WATER SUPPLIES CHANGE OF WATER SUPPLY The changing or alternating from one water supply to another can have a detrimental effect on the operation and / or life expectation of a water heater cylinder, a temperature pressure relief valve and a heating unit. Where there is a changeover from one water supply to another, e.g.
  • Page 15: Save A Service Call

    SAVE A SERVICE CALL Check the items below before making a service call. You will be charged for attending to any condition or fault that is not related to the manufacture or failure of a part. NOT ENOUGH HOT WATER (OR NO HOT WATER) Is the electricity switched on? Inspect the isolating switch marked “HOT WATER”...
  • Page 16 Heavy flows of hot water until water heater is cold - then stops until water reheats The water heater must be switched off at the switchboard. Phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection.
  • Page 17 “Single Element Model” “Twin For types of tariffs, refer to on page 7 and Element Model” on page 7. IF YOU HAVE CHECKED ALL THE FOREGOING AND STILL BELIEVE YOU NEED ASSISTANCE, PHONE RHEEM SERVICE OR THEIR NEAREST ACCREDITED SERVICE AGENT.
  • Page 18: Installation

    INSTALLATION THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING The installation must comply with the requirements of AS/NZS 3500.4, AS/NZS 3000 and all local codes and regulatory authority requirements. In New Zealand, the installation must conform with the New Zealand Building Code. All packaging materials must be removed from the water heater prior to its installation.
  • Page 19 INSTALLATION Remember all local authorities have regulations about putting water heaters into roof spaces. SAFE TRAY It is a requirement of AS/NZS 3500.4 that for a new installation, a water heater be installed in a safe tray where in the event of a leak, property may otherwise be damaged.
  • Page 20 INSTALLATION HOT WATER DELIVERY This water heater can deliver water at temperatures which can cause scalding. It is necessary and we recommend that a temperature limiting device be fitted between a Rheemglas or Optima water heater and the hot water outlets in any ablution area such as a bathroom or ensuite, to reduce the risk of scalding.
  • Page 21 A RheemPlus water heater cannot be installed as part of a circulated hot water flow and return system in a building. If a Rheem water heater is to be installed as part of a circulated hot water flow and return system, a storage water heater able to provide a hot water outlet temperature of at least 60°C must be used.
  • Page 22 INSTALLATION Circulated Hot Water Flow and Return Continuous Electric Water Heater Off-Peak or Time Controlled Electricity Supply A single or twin element electric water heater connected to an Off-Peak LEGEND electricity supply should not be installed as part of a circulated hot water flow and return system in a building.
  • Page 23 INSTALLATION REDUCING HEAT LOSSES The cold water line to and the hot water line from the water heater must be insulated in accordance with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed. ANODE The vitreous enamel lined cylinder of the water heater is only covered by warranty when the total dissolved solids (TDS) content in the water is less than 2500 mg/L and when the correct colour coded anode is installed.
  • Page 24 INSTALLATION PUSH THROUGH (FREE OUTLET) INSTALLATION It can be advantageous to plumb the water heater as a Push Through water heater in some cases. These installations can supply a single point only and normally use a 25 litre or 50 litre electric water heater.
  • Page 25 INSTALLATION TYPICAL INSTALLATION – OUTDOOR LOCATION OUTDOOR LOCATIONS TYPICAL INSTALLATION – INDOOR LOCATION OUTDOOR LOCATIONS INDOOR LOCATIONS INDOOR LOCATIONS...
  • Page 26: Dimensions And Technical Data

    INSTALLATION DIMENSIONS AND TECHNICAL DATA Rheemglas and Optima RheemPlus Rheemglas Single Element 111 025 111 080 111 125 111 160 111 250 111 315 111 400 191 050 Rheemglas Twin Element 162 160 162 250 162 315 162 400 Optima Single Element 411 250 411 315 411 400...
  • Page 27: Connections - Plumbing

    CONNECTIONS – PLUMBING CONNECTION SIZES Rheemglas, Optima RheemPlus Hot water connection: RP ¾/20 G ¾ B Cold water connection: RP ¾/20 G ¾ B RP ½/15 RP ½/15 Relief valve connection: All plumbing work must be carried out by a qualified person and in accordance with the Plumbing Standard AS/NZS 3500.4 and local authority requirements.
  • Page 28 CONNECTIONS – PLUMBING LEFT AND RIGHT HAND SIDE WATER CONNECTIONS The cold water supply, hot water supply and temperature pressure relief valve can be connected to either side of a water heater with both left and right hand side water connections. A kit is supplied with the water heater to plug off the unused cold, hot and temperature pressure relief valve fittings.
  • Page 29 CONNECTIONS – PLUMBING The valve must be insulated with closed cell polymer insulation or similar (minimum thickness 9 mm) and the insulation installed so as not to impede the operation of the valve. The insulation must be weatherproof and UV resistant if exposed.
  • Page 30 CONNECTIONS – PLUMBING RELIEF VALVE DRAIN DN15 copper drain lines must be fitted to the temperature pressure relief valve and expansion control valve (if one is installed) to carry the discharge clear of the water heater. Connect the drain lines to the valves using disconnection unions.
  • Page 31: Connections - Electrical

    CONNECTIONS – ELECTRICAL The power supply to the water heater must not be switched on until the water heater is filled with water and a satisfactory megger reading is obtained. All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the Wiring Rules AS/NZS 3000 and local authority requirements.
  • Page 32 CONNECTIONS – ELECTRICAL For reasons of safety and economy, we advise the thermostat be set at the lowest temperature that will provide sufficient hot water. Dishwasher running costs can be adversely affected if the thermostat is set below 65°C. Discuss the thermostat setting requirements with the householder.
  • Page 33 CONNECTIONS – ELECTRICAL WIRING DIAGRAM TWIN ELEMENT ELECTRIC WATER HEATERS NON-SIMULTANEOUS OPERATION OFF-PEAK CONNECTION Electrical Circuit for Twin Element Models – Robertshaw “ST” Thermostats The active from the continuous supply must be connected to the top heating unit circuit and the active from the Off-Peak or time controlled supply must be connected to the bottom heating unit circuit.
  • Page 34: Commissioning

    COMMISSIONING TO FILL AND TURN ON THE WATER HEATER The power supply to the water heater must not be switched on until the water heater is filled with water and a satisfactory megger reading is obtained. Open all of the hot water taps in the house (don‟t forget the shower). Open the cold water isolation valve fully on the cold water line to the water heater.
  • Page 35 COMMISSIONING OUTLET TEMPERATURE COMPENSATION ADJUSTMENT – RHEEMPLUS The maximum outlet temperature of a RheemPlus water heater may be adjusted to compensate for temperature losses in the pipe work between the water heater outlet and sanitary fixtures. Warning: After adjustment of the temperature limiting valve, the water temperature MUST NOT exceed 50°C from the first tap in the hot water pipe work after the water heater used for personal hygiene purposes, such as in a bathroom or ensuite.
  • Page 36 COMMISSIONING Turn the adjusting knob on the temperature limiting valve counter-clockwise (down away from the water heater), using a 6 mm Allen key. Turning the adjusting knob counter clockwise (down away from the water heater) increases the outlet water temperature, turning clockwise (up towards the water heater) decreases the...
  • Page 37: Draining The Water Heater

    DRAINING THE WATER HEATER To drain the water heater: “To Turn Off The Water Heater” Turn off the water heater (refer to page 34). Close all hot water taps. Operate the relief valve release lever - do not let the lever snap back or you will damage the valve seat.
  • Page 38 This page is intentionally blank.
  • Page 39: Warranty

    Rheem or further than 25 km from a regional 7. The water heater must be sized to supply the hot Rheem branch office, or an Accredited Service...
  • Page 40 Rheem water heater. This warranty must be read subject to that legislation and nothing in this warranty has the effect of excluding, restricting or modifying those rights.