Samsung RF267AE series Service Manual page 64

Samsung refrigerator service guide
Hide thumbs Also See for RF267AE series:
Table of Contents

Advertisement

TROUBLESHOOTING
6) If F DEF Sensor has trouble
ERROR Code
DATA1.
Temperature table
** Measuring point of resistance value according to
Sensor **
F-DEF : CN30#4 ↔ CN76#1 measuring resistance
value
** 0Ω: Short trouble / ∞Ω: Open trouble
Refer to circuit diagram in the manual
Sensor MICOM/Connector number
F DEF Connector Cn30#4(Orange) to REG1
HEAT-SINK PCB common Ground
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #77,
CN30-"4"(Orange) and REG1, HEAT SINK from
PCB typical Ground part are similar.
→ Check the measure on the SENSOR MARKING
#2(R310) due to the SMD MICOM
☞ Checking method of F DEF Sensor resistance
CN30#4(Orange) ↔ CN76#1(Gray)
- Compare the temperature table after the
measure.
Start
Start
Are MAIN PCB
Connector CN30 to CN76 insert
correctly?
YES
YES
Is F DEF Sensor
unit normal?
YES
YES
Is the voltage between
MAIN PCB Connector CN30#4 (Orange) and
REG1, HEAT SINK normal?
YES
YES
Is the input voltage of
IC01 MICOM #77 normal?
YES
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connection.
☞ Checking method of F DEF Sensor voltage
- Measure the voltage of Sensor Check Point #2(IC01 MICOM #77)
on PCB or CN30#4(Orange) ↔ REG1, HEAT SINK
- Compare the temperature table after measurement. Measuring
voltage of CN30#4(Orange) ↔ REG1, HEAT SINK are asbelow
63
NO
Bad contact of connector/ insert correctly
NO
Replace temperature sensor
NO(0.6V > Measurement < 4.6V)
Check the contact of PCB & Wire
Terminal correctly.
NO
Check the iced-solder, solder bridging,
disturbed solder. Replace the PCB
typical PCB Ground
REG1 HEAT-SINK