TROUBLESHOOTING
2) If R Sensor has trouble
ERROR Code
2¢ (-17¡ ) is recommended
DATA1.
Temperature table
** Measuring point of resistance value according to
Sensor **
R : CN30#6 ↔ CN76#1 measuring resistance value
** 0Ω: Short trouble / ∞Ω: Open trouble
Refer to circuit diagram in the manual
Sensor MICOM/Connector number
Connector Cn30#6(White) to
R
REG1 HEAT-SINK PCB common Ground
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #76,
CN30-"6"(White) and REG1, HEAT SINK from
PCB common Ground part are similar.
→ Check the measure on the SENSOR MARKING
#3(R311) due to the SMD MICOM
☞ Checking method of R Sensor resistance
CN30#6(White) ↔ CN76#1(Gray) Compare the
temperature table after the measure.
38¢ (3¡ ) is recommended
Connector CN30 to CN76 inserted
Is the voltage between
MAIN PCB Connector CN30#6 (White) and
REG1, HEAT SINK normal?
IC01 MICOM #76 normal?
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connection.
☞ Checking method of R Sensor voltage
- Measure the voltage of Sensor Check Point #3(IC01
MICOM #76) or CN30#6(White) ↔ REG1, HEAT SINK.
- Compare the temperature table after the measure.
Measuring voltage of CN30#6(White) ↔ REG1,
HEAT SINK are below.
59
Start
Is MAIN PCB
NO
correctly?
YES
NO
Is R Sensor
unit normal?
YES
NO(0.6V > Measurement < 4.6V)
YES
NO
Is the input voltage to
YES
Bad contact of connector/ insert correctly
Replace the temperature sensor
Check the contact of PCB & Wire Terminal correctly.
Check the iced-solder, solder bridging,
disturbed solder. Replace the PCB
typical PCB Ground
REG1 HEAT-SINK