Z-Wave Plus Command Class Notification
These notifications are sent unsolicited to the lifeline Association group.
Notification Type
Event
Cause
Water Detected (0x02)
Probe submerged in water
Water (0x05)
Water No longer Detected (0x04)
Probe no longer submerged in water
Tampering, Product Cover Removed (0x03)
Case Tampered
Home Security (0x07)
Event Inactive (0x00)
Case Restored to Closed Position
Replace Battery Soon (0x0A)
Battery is Getting Low
Power Management (0x08)
Replace Battery Now (0x0B)
Battery Needs Replacing
Z-Wave Plus Command Class Sensor Binary
© 2018 Ecolink Intelligent Technology Inc.
PN H214104 Rev - A