PATROL
- 101
WEATHERPROOF
CURTAIN PIR & MW
DETECTOR FOR
OUTDOOR USE
1
TERMINAL BLOCK
CONNECTION
Terminals "+12V-" – for
connection to the power
supply of the control unit.
Terminals "Tamper" –
for connection to a 24-hour
normally closed protective
zone in the control unit.
Terminals "Relay 1" –
PIR detector relay output.
Terminals "Relay 2"–
anti-mask relay output.
heater
Terminals +12V- (H)
power connects to external
12-16V/1A power unit.
IMPORTANT!
When connecting the heater,
take into consideration voltage
drop and power loss
in cables.
6
PATROL-101 combined
detector designed for use
in open, outdoor areas and
low-temperature environments
to -55°С.
PATROL-101 creates a
narrow protective curtain
allowing free movement within
the protected area without
triggering the alarm.
PATROL-101 with anti-mask
technology, to detect all types
of masking attempts.
PATROL-101 provides pet
immune detection up to 30kg.
2
PATROL-101 MOUNTING
OPTIONS
Detector can be installed
vertically or horizontally
(see illustration).
Recommended installation
height is 2.5m. Maximum
installation height is 5m.
For installation over 3.5m,
*
mount the detector at an angle
of 20 degrees.
NOTE! Avoid installing detector
where direct sunlight can enter
the pyro sensor.
7
FEATURES
·
DUAL TECHOLOGY
PIR & MW
·
QUAD ELEMENT
PYRO SENSOR
·
BUILT-IN HEATER
·
SHOCK SENSOR
·
ANTI-MASK PROTECTION
·
DOPPLER PULSE-COUNT
SELECTION (1-7)
·
INDIVIDUAL PIR / MW/
ANTI-MASK SENSITIVITY
ADJUSTMENT
·
IMMUNE TO PETS UP TO 30KG
·
AUTOMATIC TEMPERATURE
COMPENSATION
·
VISIBLE LIGHT DISTURBANCE
PROTECTION
·
DOUBLE RFI/EMI PROTECTION
·
WEATHERPROOF HOUSING
3
8
DETECTOR INSTALLATION
MANUAL
1. Run the installation wire
through the bracket wiring
hole.
Mount bracket onto the wall
2.
and affix with screws, using
the knockouts.
Corner installation
Wall installation
4
DETECTION AREA
9
3. Run the installation
wire
through
detector back cover.
Mount back cover of the
4.
detector to the bracket using
four screws.
Insert the PCB
and
connect
5.
wires according to the
schematic.
Close front cover
and affix
6.
with screw.
5
10

Advertisement

loading
Need help?

Need help?

Do you have a question about the PATROL 101 and is the answer not in the manual?

Questions and answers

Summary of Contents for GSN PATROL 101

  • Page 1 PATROL-101 combined 3. Run the installation wire FEATURES DETECTOR INSTALLATION ™ detector designed for use through detector back cover. MANUAL PATROL - 101 · DUAL TECHOLOGY in open, outdoor areas and Mount back cover of the 1. Run the installation wire PIR &...
  • Page 2 CHANGING RELAY TECHNICAL WARRANTY: ………..NC/NO; 60В; 100mА; 16Ω SWITCH CONNECTIONS SPECIFICATIONS 1. Set Jumper W1 to "WORK" GSN Electronic Company Ltd. Anti-mask alarm activation position. 1. Disconnect the power. Input voltage……………….9 – 16V warrants the product to be free delay:…………………..40-60sec...