Z T 061 N05 A 2 A ZZ 7 0 1 2 4 A
Product Category
Z = A/C, Single Pkg., R-410A
Product Identifier
T = 18 SEER Ultra High Eff. A/C
Nominal Cooling Capacity
037 = 3 Ton
049 = 4 Ton
061 = 5 Ton
Heat Type and Nominal Heat Capacity
C00 = Cooling Only. No heat installed
Two Stage Natural Gas Heat Options
N05 = 49 MBH Output Aluminized Steel,
Two Stage (037, 049)
N07 = 65 MBH Output Aluminized Steel,
Two Stage (037, 049, 061)
N09 = 97 MBH Output Aluminized Steel,
Two Stage (037, 049, 061)
N13 = 129 MBH Output Aluminized Steel,
Two Stage (061)
S05 = 49 MBH Output Stainless Steel,
Two Stage (037, 049)
S07 = 65 MBH Output Stainless Steel,
Two Stage (037, 049, 061)
S09 = 97 MBH Output Stainless Steel,
Two Stage (037, 049, 061)
S13 = 129 MBH Output Stainless Steel,
Two Stage (061)
Electric Heat Options
E03 = 3 KW (037)
E06 = 6 KW (037, 049, 061)
E08 = 9 KW (037, 049, 061)
E15 = 15 KW (037, 049, 061)
E20 = 20 KW (049, 061)
E23 = 24 KW (061)
4
®
3-5 Ton York
Model Number Nomenclature
For Units Produced Before 2-01-2016
7 = Seventh Generation
ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be
located in digits 15-18.
Voltage
2 = 208/230-3-60
4 = 460-3-60
5 = 575-3-60
A = Std. Motor
D = Std. Motor/Motorized Damper (Downflow Only)
H = Std Motor/Low Leak Econ/Barometric Relief (Downflow
& Horizontal End Return Only)
J = Std Motor/Low Leak Econ/Power Exhaust (Downflow
& Horizontal End Return Only)
N = Hi Static
R = Hi Static/Motorized Damper (Downflow Only)
V = Hi Static Mtr/Low Leak Econ/Barometric Relief
(Downflow & Horizontal End Return Only)
W = Hi Static Mtr/Low Leak Econ/Power Exhaust
(Downflow & Horizontal End Return Only)
Product Style
A = Style A
B = Style B
C = Style C
Configuration Options (not required for all units)
SS Drain Pan
CPC Controller, DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
York Commercial Comfort System (YCCS) Rtu Controller
Simplicity®Smart Equipment w/Comm Card (BACnet, N2, Mod-Bus)
Fault Detection and Diagnostics (FDD)
York Commercial Comfort System (YCCS) Rtu Controller
2" Pleated Filters, MERV 7
4" Pleated Filters, MERV 13
BAS Ready Unit with Economizer
Phase Monitor
Coil Guard
Dirty Filter Switch
Shipping Bag
American Flag
Technicoat Condenser Coil
Technicoat Evaporator Coil
E-Coat Condenser Coil
E-Coat Evaporator Coil
Any Combination of Additional Options that Don't Have an Option Code Pre-assigned
Product Generation
Additional Options
Airflow
Installation Options
A = No Options Installed
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
Options
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Johnson Controls Ducted Systems

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Predator zt049Predator zt061

Table of Contents