Hydraulic body repair kits, 4/10 ton capacity

Advertisement

Symptom
Ram will not extend
Ram *bleeds off after lift
Ram will not lower after
unloading
Poor performance
Will not lift to full extension
"Bleeds off" means that ram begins to slowly retract rather than maintain position
*
TROUBLESHOOTING
Possible Causes
• Release valve not tightly closed
• Overload condition
• Release valve not tightly closed
• Hydraulic unit malfunction
• Reservoir overfilled
• Ram damaged
• Fluid level low
• Air trapped in system
• Fluid level low
7
Corrective Action
• Ensure release valve tightly closed
• Remedy overload condition
• Ensure release valve tightly closed
• Replace ram and / or pump
• Drain fluid to proper level
• Replace ram
• Ensure proper fluid level
• With ram fully retracted, remove oil
filler screw to let pressurized air
escape, then reinstall oil filler screw
• Ensure proper fluid level