Rhino Shelter PB143012RGN Assembly Instructions Manual

14x30x12 round utility

Advertisement

Quick Links

ASSEMBLY INSTRUCTIONS
ROUND UTILITY 14Wx30Lx12H
Congratulations!
Congratulations on your purchase of a Round Style
Portable Building by MDM Products LLC. With proper
installation, use, and maintenance, your new unit will
provide many years of good and suitable service. Your
new Rhino Shelter portable building is a combination of
excellent engineering and well thought out design. The
unit is comprised of a rigid tubular frame, covered with a
long life polyethylene cover and double door ends.
The multiple part frame assembly is pre-drilled for easy
insertion of hardware to assemble. The tubing is made
from high-grade galvanized steel tubing, to resist
moisture and oxidation over the life of the shelter. The
fabric components are made from ASTM-5 approved
polyethylene materials. The cover is UV protected for
exposure to the sunlight.
It is suggested that you read the assembly instructions
completely before you begin. This will help attain the
best results for your installation.
SAFETY WARNING
The installation of this unit must conform to the
requirements of all authorities having jurisdiction in
your specific local area. In the absence of such
requirements, the installation must conform to the
provided assembly and installation instructions.
MDM Products LLC will not be responsible for failure
to comply with any requirements in a given local
area. Consequential damages or injuries caused by
improper installation, alteration, or improper use are
strictly that of the user. Unit MUST be cleared of All
Snow Accumulation immediately to avoid overload.
Unit is not to be used for occupancy for any length
of time. No running internal combustion engines,
open flames, or contact with heated surfaces are
allowed.
For installation assistance or Customer Service, please
call 800-447-7079 or 203-877-7070, 8AM-5PM EST.
Cartons should be inspected upon delivery from carrier,
and any evident damages should be noted on the bill of
lading before signing. If upon opening the cartons
hidden damage is noted, contact carrier or its agent
immediately. Claims for shipping damage MUST be
made with the shipping company. An inspection of the
goods will most likely be required. Do not discard
packing or any components before the freight company's
inspection. All claims for freight damage must be made
V2.3
Please Do NOT Return Assembly to Dealer or Store. For All Assembly Questions or Shortages Please Call MDM Products directly
Assembly Instructions 14X30X12 Round Utility
with 15 days of receipt of the goods in accordance with
ICC regulations.
ASSEMBLY PROCEDURE
The proper sequence and steps to install this unit will
produce a proper and good installation. Failure to read
and follow these guidelines may result in an improper
installation and will void all warranty and protection the
owner is entitled to with the product. The steps to be
undertaken are:
1. Perform an inventory check before beginning to be
2. Prepare location and place both unit boxes near
3. Assemble seven (7) arches of unit
4. Assemble unit end arch, first interior arch, and Wind
5. Add additional arch assemblies with each section of
6. Place frame into desired position and level frame
7. Anchor frame assembly to ground with provided
8. Install two(2) doors on both ends of frame assembly.
9. Install Main Cover over frame assembly.
TOOLS REQUIRED
The following hand tools will be needed for proper
installation of your new Rhino Shelter unit:
INVENTORY CHECK
Start installation procedure by removing all components
from packaging and ensure all components are present
Qty
1
2
4
7
7
14
10
Customer Service 800-447-7079 or 203-877-7070
certain all components are available for installation.
location sight.
Braces with first top, base, and side rail sections.
base rails and side rails.
both end-to-end and side-to-side. Level and adjust
unit in both width and alignment. Measure interior of
frame feet across opposite corners and square
anchors, u-bolts and drive rod provided.
9/16" Open End Wrench
9/16" Socket or Box Wrench
Large Flat Tip Screwdriver
Maul or Sledgehammer
2 foot Level
10 foot Step Ladder
Part Number
Description
RUC-9000
Main Unit Cover
DZD-7002
End Panel Door with Zippers
EUL-5021
End Upright w/Foot
RC-5020
Right Side Crest Tube
LC-5021
Left Side Crest Tube –swedged
MC-9000
Middle Connect Tube
CSU-5020
Center Straight Uprights
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PB143012RGN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rhino Shelter PB143012RGN

  • Page 1 Your owner is entitled to with the product. The steps to be new Rhino Shelter portable building is a combination of undertaken are: excellent engineering and well thought out design. The unit is comprised of a rigid tubular frame, covered with a 1.
  • Page 2: Site Preparation

    Select a level or as close to level as practical location for branches or other falling items may cause puncture or your Rhino Shelter unit. The unit should be placed on a tears in the cover material. base of materials suitable for the storage load to be protected.
  • Page 3: Frame Assembly

    Assembly Instructions 14X30X12 Round Utility should be planned so that it does not run into the unit. Attach one end upright/mid tube connect sub assembly As well, rain or melting snow that comes off the unit to each end of a pair to assembled crest tubes to should be drained away rather than accumulate and pool construct each end arch (Qty - 2).
  • Page 4 Assembly Instructions 14X30X12 Round Utility Using (4) 3¼” Carriage Bolts (CBN-3005-3) with nuts and washers, connect the cross rails between the end Under End arch and the first interior arch assemblies. Connect the Arch (2) Wind Braces (CW-2800) diagonally across the end and interior arch as shown in the frame illustration.
  • Page 5: Anchoring Frame To Ground

    1/8”) into all open ends of frame members. NOTE: Frame must be anchored before installing any doors or cover. Each Rhino Shelter 14x30x12 building comes with 14 EARTH CABLE ANCHORS with U-bolts and nuts. These versatile anchors allow the frame to be secured to almost any surface.
  • Page 6 Assembly Instructions 14X30X12 Round Utility ANCHOR STEP 1 Step 1. Place the drive rod provided into the cup of the anchor. Using a heavy hammer drive the anchor into the soil until 6-8 inches of cable remains above the earth. Remove drive rod.
  • Page 7: Main Cover Installation

    Assembly Instructions 14X30X12 Round Utility rail pole and the side cross rail poles through the material slits and replace the carriage bolts and tighten. Each door end will also require removal of the wind brace bolts and placement of the wind braces through Top Ridge Rail slits in the ends panel.
  • Page 8 Assembly Instructions 14X30X12 Round Utility Assembly with the Main Cover colored side showing from the outside of the unit. Step 2. Loosen the 4 ratchets. Place the hook that is attached to the ratchet strap into the outer hole in the foot of each end arch.
  • Page 9: Mainteance And Care

    Rhino Shelter unit. checked to be certain they remain deeply and firmly set. Please retain purchase documentation for your Rhino Snow Accumulation –...

Table of Contents