Optex Reaction One Operation Manual

Optex Reaction One Operation Manual

Microwave door sensor

Advertisement

Quick Links

REACTION ONE /
REACTION TWO
MANUFACTURER'S STATEMENT
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of a
person.The meanings of the symbols are as follows. Please study the following first and then read the contents of this
operation manual.
Disregard of warning may cause the improper operation causing death or serious injury of a
WARNING
person.
Disregard of caution may cause the improper operation causing injury of person or damage to
CAUTION
objects.
NOTE
Special attention is required to the section of this symbol.
NO TE
1. This sensor is a non-contact switch intended for header mount / ceiling mount of an automatic door.
Do not use for any other applications.
2. When setting the sensor's detection area, make sure there is no traffic around the installation site.
3. Before turning the power on, check the wiring to prevent damage or malfunction of equipments that are connected
to the sensor.
4. Only use the sensor as specified in the operation manual provided.
5. Be sure to install the sensor in accordance with the local laws and standards of the country in which the sensor is
installed.
6. Before leaving the job site make sure that the sensor is operating properly and instruct the building owner/operator
on proper operation of the door and the sensor.
7.The sensor setting can only be changed by an installer or service engineer. When changed, register the changed
setting and dates in the maintenance logbook accompanying the door.
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it may cause electric shock or breakdown of equipments.
Danger of electric shock.
NOTE
The following conditions are not suitable for the sensor installation.
-Vibrating header or mounting surface.
-Moving objects, steel plate, emergency lights or illumination in the detection area or in vicinity.
SPECIFICATIONS
Model
: REACTION ONE / REACTION TWO
Cover color
: Silver / Black
Mounting height
: 2.0 (6'7") to 3.5m (11'5")
Detection method
: Microwave doppler effect
Power frequency
: 24.125GHz
Power density
: <20dBm
Detection area
: See Detection area
Vertical adjustment
: +10 to +70 (Header mount)
+20 to +80 (Ceiling mount)
Horizontal adjustment
: 30 to left or right
Power supply
: 12 to 24VAC( 10%)
12 to 30VDC( 10%)
Power consumption
: < 1.5W(<2VA at AC)
Minimum speed
: 5cm(1 15/16")/sec.
Operation indicator
: Green / Stand-by
Red / Detection
Green blinking / Set-up
NOTE
The specifications herein are subject to change without prior notice due to improvements.
OUTER DIMENSIONS AND PART NAMES
97(3 13/16")
131(5 3/16")
INSTALLATION
1
1. Affix the Mounting template at the desired mounting position.
2. Drill 2 Mounting holes of ø3.4mm (ø1/8").
3. To pass the cable through to the header, drill a Wiring hole of ø8mm (ø5/16").
4. Remove the Mounting template.
5. Remove the Housing cover with screw driver as shown below.
Attach the sensor to the mounting surface with 2 Mounting screws.
Cover fixing
Insert
1
Screw driver
2
Wire the cable to the door controller properly as shown below.
Before starting the procedure, ensure that the power is turned OFF.
WARNING
When passing through the cable to the hole, make sure not to tear the shield,
Danger of electric shock.
otherwise it may cause electric shock or breakdown of the sensor.
3
1.Plug the connector of the sensor.
2.Supply power to the sensor and the sensor will automatically start the set-up mode with blinking Green.
3.Adjust the detection area and set the Dipswitches. (See ADJUSTMENTS)
Make sure to connect the cable correctly to the door controller before turning the power ON.
NOTE
The sensor does not detect objects for 10 seconds after supplying power.
4
Hook the Housing cover on the left side of main body to place the Housing cover.
If wiring is to be exposed, break the knockout.
Do not use the sensor without the Housing cover.
WARNING
When using the cable knockout, install the sensor indoors or use the rain-cover
(Separately available) otherwise electric shock or breakdown of the sensor may occur.
Danger of electric shock.
-Waterdrops or snow on the sensor.
: Form C relay
Output
50V 0.3A Max.(Resistance load)
: 2.0sec. / 4.0sec.
Output hold time
: <0.3 sec.
Response time
: <80%
Operating humidity
: -20 C to +55 C(-4 F to 131 F)
Operating temperature
: IP54
IP rate
: 140g (4.9oz)
Weight
: 1 Cable 3m (9'10")
Accessories
1 Operation manual
2 Mounting screws
1 Mounting template
1 Narrow lens*
* At the back of housing cover
3
8
5
0
7
1. Antenna
2. Sensitivity potentiometer
3. Mounting holes
4. Dipswitches
5. Wiring hole
6. Narrow lens
6*
7. Operation indicator
mm(inch)
*Narrow lens is stored
8. Terminal block
9. Cover fixing
at the back of housing
cover.
Screw driver
Slide
3
Red
Black
White
Green
ENGLISH
ADJUSTMENTS
1
Detection area
Adjust the detection area with Sensitivity potentiometer.
10°
4000
3000
2000
(13'1")
(9'10")
(6'7")
NOTE
When the sensor is mounted at higher than 3.0m, set the SENSITIVITY to "H (high)".
2
Detection area angle adjustment
Vertical
adjustment
Front View
Horizontal
adjustment
CAUTION
3
Narrow area
To obtain Narrow area, place Narrow lens attached at the back of housing cover.
To place Narrow lens, follow step1&2 as shown on the right.
4
Dipswitches settings
Set Dipswitch1&2 to enable the direction recognition. (REACTION TWO Only.)
1
2
Detection
area
1
2
When Dipswitch1 is set to OFF,
Bi-direction mode is effective,
4
regardless of Dipswitch2 setting.
3
*Auto-caution mode(A person wavering in the detection area to be detected.)
9
Dipswitch3:Output hold time
2
2.0sec.
1
3
INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS
WARNING
1. Always keep the housing cover clean. If dirty, wipe the housing cover lightly with a cloth.
(Do not use any cleaner or solvent.)
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
4. Always contact your installer or service engineer when changing the settings.
5. Do not paint the housing cover.
NOTE
NOTA
1. After applying power, wait 10 seconds then walk test detection area to ensure proper operation..
2. Do not place any objects that move or emit light in the detection area. (e.g. Plant, illumination, etc.)
CHECKING
Check the operation according to the chart below.
Sensor Status
Operation indicator
Open
Output Contact
2
TROUBLESHOOTING
Operation
Power supply
Problem
12 to 24V AC 10
indicator
12 to 24VDC 10
None
Door does not
open when a
Unstable
Relay
person enters
N.O.
Green
the detection
N.C.
area.
Green
blinking
Door opens
Red
when no one
is in the
detection area.
(Ghosting)
Door remains
Green
open
Wide area
L
Mounting height:2.2m(7'3")
Vertical adjustment : +34
mm(feet,inch)
L
1000
10°
M
(3'3")
H
2000
(6'7")
3000
43°
(9'10")
4000
(13'1")
1000
2000
3000
1000
0
4000
3000
(3'3")
(3'3")
(6'7")
(9'10")
(13'1")
(9'10")
Adjustment
Scale
3 X 20 steps
0
Side View
5 X 12 steps
0
0
Front View
Front View
Do not touch electric part of the sensor to avoid possible breakdown of the sensor.
Bi-direction(Bi)
Uni-direction(Uni)
Door
1
2
Uni-direction with Auto
Bi-direction
-caution mode*(ACM)
1
2
Dipswitch4:Immunity
4.0sec.
4
3
Set-up
Power OFF
(Approx. 10sec.)
Green blinking
OFF
Possible cause
Wrong power supply voltage.
Set to the stated voltage.
Wrong wiring or connection failure.
Check the wiring and Terminal block.
Sensitivity is too low.
Set the sensitivity higher.
Wrong detection area positioning.
Check ADJUSTMENTS.
The sensor is being set up.
Wait for the set-up to complete.
Water drops on the housing cover.
Wipe the housing cover with a cloth.
The detection area is overlaping with
Adjust the detection area away from the door.
the door.
Or set Dipswitch4 to ON.
Sensitivity is too high.
Set the sensitivity lower.
Raining or snowing.
Set Dipswitch1 to ON.(REACTION TWO Only)
Or Dipswitch4 to ON.
Wrong wiring or connection failure.
Check the wiring and Terminal block.
Narrow area
H
Mounting height:2.2m(7'3")
Vertical adjustment : +34
mm(feet,inch)
0
L
1000
10°
10°
(3'3")
M
2000
(6'7")
H
3000
(9'10")
43°
4000
(13'1")
2000
1000
1000
2000
3000
0
(6'7")
(6'7")
(3'3")
(3'3")
(9'10")
Angle
Ceiling
Header
+80
+70
+20
Side View
+10
0
+30
+30
Front View
2
1
: Detection
: Non-Detection
If there is external interference,
set Dipswich 4 to ON.
Detection
Stand-by
Green
Red
Possible countermeasures

Advertisement

loading

Summary of Contents for Optex Reaction One

  • Page 1 SPECIFICATIONS Narrow area To obtain Narrow area, place Narrow lens attached at the back of housing cover. Model : REACTION ONE / REACTION TWO : Form C relay Output To place Narrow lens, follow step1&2 as shown on the right.
  • Page 2 FCC WARNING(For USA) Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. -NOTICE- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.