Safety And Protective Functions; Electromagnetic Radiation; Mechanical Movement; Emission - Ebmpapst R3G250-AT39-71 Operating Instructions Manual

Ec centrifugal fan
Table of Contents

Advertisement

R3G250-AT39-71
CAUTION
In the event of failure, there is electric voltage at the
rotor and impeller
The rotor and impeller are base insulated.
→ Do not touch the rotor and impeller once they are installed.
CAUTION
If control voltage is applied or a speed setpoint is stored,
the motor will restart automatically, e.g. after a mains
failure.
Risk of injury
→ Keep out of the device hazard zone.# When working on the
device, switch off the mains power and ensure that it cannot
be switched back on.
→ Wait until the device stops.
→ After working on the device, remove any tools used or
other objects from the device.

1.5 Safety and protective functions

DANGER
Protective device missing and protective device not
functioning
Without a protective device there is a risk of serious injury, for
instance when reaching into the device during operation.
→ Operate the device only with a fixed protective device and
guard grille.# The fixed protective device must be able to
withstand the kinetic energy of a fan blade that becomes
detached at maximum speed. There must not be any gaps
which it is possible to reach into with the fingers, for example.
→ The device is a built-in component. As the operator, you
are responsible for ensuring that the device is secured
adequately.
→ Stop the device immediately if a protective device is
found to be missing or ineffective.

1.6 Electromagnetic radiation

Interference from electromagnetic radiation is possible, e.g. in conjunction
with open and closed-loop control devices.
If unacceptable emission intensities occur when the fan is installed,
appropriate shielding measures have to be taken by the user.
NOTE
Electrical or electromagnetic interferences after
integrating the device in installations on the customer's
side.
→ Verify that the entire setup is EMC compliant.

1.7 Mechanical movement

DANGER
Rotating device
Body parts that come into contact with the rotor and impeller
can be injured.
→ Secure the device against accidental contact.
→ Before working on the system/machine, wait until all
parts have come to a standstill.
WARNING
Rotating device
Long hair, dangling items of clothing, jewellery and similar items
can become entangled and be pulled into the device. Risk of
injury.
Item no. 50237-5-9970 · ENG · Revision 90396 · Release 2016-09-21 · Page 2 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions

1.8 Emission

1.9 Hot surface

1.10 Transport

1.11 Storage

; Store the device, partially or fully assembled, in the original
packaging in a clean, dry and weatherproof place free of vibrations.
; Protect the device against environmental effects and dirt until final
installation.
; We recommend storing the device for no longer than one year in
order to guarantee trouble-free operation and longest possible service
life.
; Even devices explicitly intended for outdoor use are to be stored as
described prior to commissioning.
; Maintain the storage temperature, see
chapter 3.6 Transport and storage conditions.
→ Do not wear any loose-fitting or dangling clothing or jewellery
while working on rotating parts.# Protect long hair with a cap.
WARNING
Depending on the installation and operating conditions,
a sound pressure level greater than 70 dB(A) may arise.
Danger of noise-induced hearing loss
→ Take appropriate technical safety measures.
→ Protect operating personnel with appropriate safety
equipment, e.g. hearing protection.
→ Also observe the requirements of local agencies.
CAUTION
High temperature at the electronics housing
Risk of burns
→ Ensure sufficient contact protection.
NOTE
Transporting the device
→ Transport the device in its original packaging only.