Lindab DRU Assembly Instructions Manual

Dampers
Hide thumbs Also See for DRU:

Advertisement

Quick Links

l inda b | we si mpli fy c onst r uction
LindabDampers
Assembly instructions

Advertisement

loading

Summary of Contents for Lindab DRU

  • Page 1 l inda b | we si mpli fy c onst r uction LindabDampers Assembly instructions...
  • Page 2 | w e s i m p l i f y c o n s t r u c t i o n Dampers DRU, DSU, DTU, DTHU, DTH1U, DTH2U, DTBU, DTBVU DTBCU, DTFU, DTBLU, DSUSN, DSVUSN, DTPU, PSDRU, TDRU, TDSU...
  • Page 3 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Dampers FMU, FMDRU, FMDU, DIRU, DIRBU, DIRVU FTCU, FTMU, FTSU We reserve the right to make changes without prior notice...
  • Page 4: Maintenance

    The dampers are then locked by turning them slightly clockwise. Balancing On DRU, PSDRU and TDRU the damper blade is stepless adjustable through 0–90° (0°=fully open, 90°=completely closed) using the knob in the cup. Locking is performed using screws for Pozidrive (PZD2) and the damper angle can be read off a stamped grade on the edge of the cup.
  • Page 5 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Dampers CM 24 / CM 24 F CM 230 / CM 230 F Power supply ......
  • Page 6 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Dampers LMQ 24A LMQ-SR 24A Power supply ......AC 19,2-28,8 V, 50/60 Hz AC 19,2-28,8 V, 50/60 Hz ...........
  • Page 7 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Dampers NM 24 A-F NM 230 A-F Power supply ......AC 19,2–28,8 V, 50/60 Hz AC 85–265 V, 50/60 Hz DC 19,2–28,8 V Power consumption ....
  • Page 8 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Dampers TF 24 TF 230 Power supply ......2AC 19,2–28,8 V, 50/60 Hz AC 85–265 V, 50/60 Hz DC 21,6–28,8 V Power consumption...
  • Page 9 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Dampers SFA (both 24 V and 230 V power supplay) Power supply ......AC 19,2–28,8 V, 50/60 Hz DC 21,6–137,5 V Power consumption...
  • Page 10 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Dampers LKSR Assembly In order to fulfil the requirements for air-tightness class C, the damper must be installed as per ‘Assembly Instruction Rectangular air duct systems’.
  • Page 11 Assembly In order to fulfil the requirements for air-tightness class D, the devices must be installed as per ‘Assembly Instruction Lindab Safe’. The devices must be installed with the air flow in the direction of the arrow. The devices allow 50 mm duct insulation without the scale or any motor being hidden.
  • Page 12 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Constant/variable flow dampers The flow is adjusted by loosening the central nut and using the knob to turn the scale arrow so that it points to the desired flow on the scale.
  • Page 13 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Constant/variable flow dampers DAVU Setting of flow limits The two flow limits are set by moving the end stops. At delivery the stops are set at lar- gest possible distance.
  • Page 14 Air stream operated dampers CARU, CAR Assembly CARU In order to fulfil the requirements of tightness class D the damper must be installed as per ‘Assembly Instruction Lindab Safe’. The damper is installed by simply placing it inside a duct. Measurement The dampers normally don’t need any maintenance.
  • Page 15 In order to fulfil the requirements for air-tightness class D, the bends must be installed as per ‘Assembly Instruction Lindab Safe’. The bends allow 50 mm duct insulation without the measuring points being hidden. For 100 mm insulation, an insulation cup, IK, is available.
  • Page 16: Flow Meters

    Assembly In order to fulfil the requirements for air-tightness class D, the devices must be installed as per ‘Assembly Instruction Lindab Safe’. FMDRU must be installed with the air flow in the direction of the arrow. The devices allow 100 mm duct insulation without sticker or measuring points being hidden. The cup around FMDRU’s damper knob allows 50 mm duct insulation without the knob being hidden.
  • Page 17 Assembly In order to fulfil the requirements for air-tightness class D, the device must be installed as per ‘Assembly Instruction Lindab Safe’. The device must be installed with the air flow in the direction of the arrow. The device allows 50 mm duct insulation without sticker or measuring points being hidden.
  • Page 18 DIRU Assembly Mount the dampers according to “Assembly Instructions Lindab Safe” to meet with the requirements for tightness class Consider required straight distance after or before disturbance, as mentioned on the card attached to the measurement nozzles, to obtain accurate flow measurement. Dampers with dimension 400, 500 and 630 are provided with transport protections.
  • Page 19 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Damper with flow meter DIRU, DIRBU, DIRVU To set the air flow: 1.
  • Page 20 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Damper with flow meter DIRU, DIRBU, DIRVU Pressure drop graphs with noise genera- Flow graphs for balancing tion for dimensioning The dimensioning graphs show the pressure drop over...
  • Page 21 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Damper with flow meter DIRU, DIRBU, DIRVU Pressure drop graphs with noise genera- Flow graphs for balancing tion for dimensioning Ø150...
  • Page 22 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Damper with flow meter DIRU, DIRBU, DIRVU Pressure drop graphs with noise genera- Flow graphs for balancing tion for dimensioning Ø250...
  • Page 23 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Damper with flow meter DIRU, DIRBU, DIRVU Pressure drop graphs with noise genera- Flow graphs for balancing tion for dimensioning Ø400...
  • Page 24 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Damper with flow meter DIRU, DIRBU, DIRVU Measurement accuracy If the velocity profile is asymmetric, the measurement values can differ from the ideal values. For this reason, the flow meter should never be located right up to any flow disturbance.
  • Page 25 Mount the damper according to “Assembly Instructions Lindab Safe” to meet the requirements for tightness class C. Dampers with dimension 400, 500 and 630 are provided with transport protections. Remove these before assembly.
  • Page 26 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Damper with flow meter DIRBU, DIRVU Maintenance The product normally doesn't requires any maintenance but before maintenance, service or repair make sure that: End stop screws •...
  • Page 27 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Damper with flow meter DIRBU, DIRVU DIRBU Technical data for the motors LM 24 A LM 230 A Power supply ......
  • Page 28 Mount the Controller into the air duct system according to the mounting instructions for Lindab Safe. Do not use the flow sensors as handles when you mount the Controller since they may break and changes in their positions might influence the measurement accuracy.
  • Page 29 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Measurement uncertainty ± % or 1 l/s depending wich is the greatest Distur- 2-4·Ød...
  • Page 30 Mount the Monitor into the air duct system according to the mounting instructions for Lindab Safe. Do not use the flow sensors as handles when you mount the Monitor since they may break and changes in their posi- tions might effect the measurement accuracy.
  • Page 31 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Measurement uncertainty ± % or 1 l/s depending wich is the greatest Distur- 2–4×Ød...
  • Page 32 Mount the Sensor into the duct system according to the mounting instructions for Lindab Safe. Do not use the flow sensors as handles when you mount the Sensor since they may break and changes in their positions might effect the measurement accuracy.
  • Page 33 l i n d a b | w e s i m p l i f y c o n s t r u c t i o n Measurement uncertainty ± % or 1 l/s depending wich is the greatest Distur- 2–4×Ød >4–5×Ød...
  • Page 34 At Lindab, good thinking is a philosophy that gui- des us in everything we do. We have made it our mission to create a healthy indoor climate – and to simplify the construction of sustainable buil- dings. We do that by designing innovative pro- ducts and solutions that are easy to use, as well as offering efficient availability and logistics.