Reference Indicators; Character Display; Parameter Selection Controls; Adjustment Of Operating Parameters - pro bel V1635V-100 User Manual

24-bit aes audio variable delay module
Table of Contents

Advertisement

Vistek V1635V-100 24-bit AES Audio
Variable Delay Module
3.1.3
These LEDs indicate the present reference source, as selected by the Parameter Selection
Controls. When Free-Running (internal crystal oscillator) is selected, none of the LEDs are
lit, and when an external AES or Video reference is selected and is present, the appropriate
LED will be lit continuously. If the selected external AES or Video reference fails, the LED will
flash and the V1635V will default to free-running mode until the reference recovers.
3.1.4
Used for displaying parameters which have numeric or alphanumeric values.
3.1.5
These are used for selection of, and adjustment of, operating parameters when the rem/local
switch is set to local
3.2

Adjustment of Operating Parameters

3.2.1
The V1635V has three pages (Page 0, Page 1 and Page 2) of panel adjustment modes,
each page allows adjustment of one or more parameters. Conceptually the procedure is not
unlike setting a digital alarm clock or watch.
·
·
·
·
·
·
·
Issue 8.0

Reference Indicators

Character Display

Parameter Selection Controls

.

General

Panel adjustment pages can only be invoked if the
is set to
.
LOCAL
Pressing the SELECT button on its own invokes the panel adjustment modes of
Page 0
Pressing the SELECT button while holding in the p button invokes the panel
adjustment modes of Page 1. The p button is analogous to a 'SHIFT' key on a
computer keyboard when selecting pages of adjustment modes.
Pressing the SELECT button while holding in the q button invokes the panel
adjustment modes of Page 2. The q button is analogous to an 'ALT' key on a
keyboard when selecting pages of adjustment modes.
Once any panel adjustment page has been selected, repeated pressing of the
SELECT button allows the user to scroll through the various parameters available
on the page.
A row of LEDs above the SELECT button indicates which
parameter is presently selected for adjustment.
For any given parameter selected for adjustment, the value of the parameter may
be increased or decreased by pressing the p or q keys respectively. The value
of the parameter is indicated either on the character display or the respective sets
of LEDs above the character display.
Holding the or p or q buttons down will cause the value of the parameter to auto
increment and autodecrement respectively. The longer the button is held down,
the faster the rate of autoincrement or autodecrement.
/
switch on the panel
REM
LOCAL
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

V1635va-100V1635vd-100V1635vV1635vdV1635va

Table of Contents