Commissioning
• Place the light fitting over the threads of the securing
Screws and refit the rubber washers and finials to
secure. Make sure the fitting is correctly oriented in a
PIR Adjustment
1. The unit must be installed in a vertical position, and
fitted 1.8m - 2.5m above the ground.
2. The detection angle is set at 130 degrees and the
detection distance is 8m. The PIR will start activating
when the light level drops to 20 LUX and will continue
to activate until the light level rises to 2000 LUX.
When adjusting the sensitivity (detection distance)
Either side of product
Left
Side
Fitting/replacing bulbs
• The LED bulbs in this product are non replaceable
We recommend cleaning with a soft dry cloth.
Do not use solvents or abrasive cleaners as these could
damage the finish.
Recycling advice
Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or retailer for recycling advice.
Safety information
Live Voltages may be present in this unit even when turned off or when completely disconnected. For your safety,
always switch off the supply before changing lightbulbs, or cleaning.
www.saxbylighting.com
vertical direction (See Fig. 2 overleaf).
• Replace fuse or circuit breaker and switch on. Your
light is now ready for use.
in daylight it will be necessary to cover the sensor
to simulate night time. When the PIR is activated the
light will remain lit for a maximum of 5 minutes. The
minimum is 5 seconds.
Right
Side
Iss.4 22012016
Saxby Lighting Ltd. BH23 3PE
Instruction leaflet
Evesham Wall
54555, 54556